  8  

Figure 4-2 Rear Panel

    PSS-3203/2005 PROGRAMMABLE POWER SUPPLY

USER MANUAL

  9  

1.

Power Switch

Connect the AC power, then press power switch.

2.

Display

Indicate the setting of voltage/current value, output
voltage/current value and the status of setting and
output.

3.

+Output Terminal

Positive output terminal.

4.

-Output Terminal

Negative output terminal.

5.

GND Terminal

Connect the ground terminal to chassis.

6.

Rotary Encoder

Wheel knob.

7.

V Set/I Set
(ENTER)

The key for switch over output voltage and output
current setting.
ENTER: The knob for value input or setting

confirmation.

8.

F/C

The knob for switching over coarse and fine
adjustment.

9.

MENU

The category of function setting (Output, OVP,
OCP, Contrast, Buzzer, Interface.)
PS. After switching to the picture of function
setting category, if there is no further setting action
within 4 to 5 seconds, the system will return to
previous setting picture or output display picture.

10.

LOCAL

Clear REMOTE control mode, and replace with
panel control.
PS. Get into calibration mode by pressing the knob

more than 5 seconds uninterruptedly,

11.

Output

Turn on or off output by pressing the knob.

12.

AC Power Socket

AC power input terminal.

13.

AC Select Switch

Switch Voltage to 100V, 120V, 220V or 230V,
50/60Hz.

14.

Cooling Fan

A cooling fan.

15

Interface

GPIB or RS-232C communication interface.

Summary of Contents for PSS-2005

Page 1: ...12 13 13 13 6 MAINTENANCE 6 1 Fuse Replacement 6 2 Line Voltage Conversion 6 3 Adjustment and Calibration 6 4 Cleaning 14 14 14 15 18 7 THE SYSTEM DIAGRAM AND DESCRIPTION 7 1 Block Diagram 7 2 The Ope...

Page 2: ...loured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red If in doubt consult the instructions provided with the eq...

Page 3: ...0 4 4 1995 Surge Immunity EN 61000 4 5 1995 Conducted Susceptibility EN 61000 4 6 1996 Voltage Dips Interrupts EN 61000 4 11 1994 Safety Low Voltage Directive 73 23 EEC amended by 93 68 EEC IEC EN 610...

Page 4: ...0 21V 1 Voltage 3mV 5mV rating current 3 0A Load Effect Current 3mA 5mA rating current 3 0A Voltage 3mV Source Effect Current 3mA Voltage 10mV Current 1mA 2mA rating current 3 0A Resolution OVP 10mV V...

Page 5: ...ng from the factory Upon receiving the instrument please unpack and inspect it to check if there is any damage caused during transportation If any sign of damage is found notify the bearer and or the...

Page 6: ...32 to 104 F To operate the instrument exceeding this specific temperature range may cause damage to the circuits of instrument Do not use the instrument in a place where strong magnetic or electric f...

Page 7: ...for value input or setting confirmation 8 F C The knob for switching over coarse and fine adjustment 9 MENU The category of function setting Output OVP OCP Contrast Buzzer Interface PS After switching...

Page 8: ...RAMMABLE POWER SUPPLY USER MANUAL 11 Example If want to set the current as 1 234A first using the F C knob to switch the cursor to 1mA step and adjust the value to 34 then switch the cursor to 100mA s...

Page 9: ...indow will be appeared then using the wheel knob to modify the value and press ENTER to complete the setting Note The system will detect the interface used at present automatically and switch the dete...

Page 10: ...tage to another is done by change AC selects switch The rear panel identifies the line voltage to which the unit was factory set To convert to a different line voltage perform the following procedure...

Page 11: ...e Max measured by the DMM with the knob and press ENTER During the current value input use the PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 17 F C button to switch over the input of 100mA range...

Page 12: ...may leak into the cabinet and cause damage Do not use chemicals containing benzine benzene toluene xylene acetone or similar solvents Do not use abrasive cleaners on any portion of the instrument PSS...

Page 13: ...materials can use the Vr to make adequate adjustment PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 21 The operation in C C Mode is similar to that in C V Mode The MPU will send 2100 counts 2 1A...