CONTENTS PAGE
1.

PRODUCT INTRODUCTION.................................................
1-1. Description………………………………………………
1-2. Feature…………………………………………………...

1
1
1

2.

TECHNICAL SPECIFICATIONS…………………………

3

3.

PRECAUTIONS BEFORE OPERATION…….…………...
3-1. Unpacking the Instrument……………….………….….
3-2. Checking the Line Voltage…………………..………….
3-3. Environment……………………………………..……...

5
5
5
6

4.

PANEL INTRODUCTION……………………..…………... 7

5.

OPERATION METHOD………………………………...….
5-1. Output Voltage/Current Setting…………………..……
5-2. Over Voltage/Current Protection Setting……………...
5-3. The Display Contrast Setting.…………………………..
5-4. The Buzzer Setting………………………………………
5-5. GPIB/RS-232 Interface Setting…………………………
5-6. The Maximum Setting Value…………………………...
5-7. Test Lead………………………………………………...
5-8. The Setting for the GPIB and RS232 Interface………..

10
10
11
12
12
12
13
13
13

6.

MAINTENANCE………………………..…………………..
6-1. Fuse Replacement……………………………………….
6-2. Line Voltage Conversion………………………………..
6-3. Adjustment and Calibration……………………………
6-4. Cleaning…………………………………………………

14
14
14
15
18

7.

THE SYSTEM DIAGRAM AND DESCRIPTION………..
7-1.Block Diagram…………………………………………...
7-2.The Operation of the whole circuit……………………...

19
19
20

    PSS-3203/2005 PROGRAMMABLE POWER SUPPLY

USER MANUAL

     

       

ii

SAFETY TERMS AND SYMBOLS

These terms may appear in this manual or on the product:

WARNING. Warning statements identify condition or

practices that could result in injury or loss of life.

CAUTION. Caution statements identify conditions or

practices that could result in damage to this product or

other property.

   

   

The following symbols may appear in this manual or on the product:

 

      
   

DANGER

ATTENTION

Protective

Earth (ground)

Frame or Chassis

High Voltage

refer to Manual

Conductor

Terminal

Terminal

Terminal

Summary of Contents for PSS-2005

Page 1: ...12 13 13 13 6 MAINTENANCE 6 1 Fuse Replacement 6 2 Line Voltage Conversion 6 3 Adjustment and Calibration 6 4 Cleaning 14 14 14 15 18 7 THE SYSTEM DIAGRAM AND DESCRIPTION 7 1 Block Diagram 7 2 The Ope...

Page 2: ...loured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red If in doubt consult the instructions provided with the eq...

Page 3: ...0 4 4 1995 Surge Immunity EN 61000 4 5 1995 Conducted Susceptibility EN 61000 4 6 1996 Voltage Dips Interrupts EN 61000 4 11 1994 Safety Low Voltage Directive 73 23 EEC amended by 93 68 EEC IEC EN 610...

Page 4: ...0 21V 1 Voltage 3mV 5mV rating current 3 0A Load Effect Current 3mA 5mA rating current 3 0A Voltage 3mV Source Effect Current 3mA Voltage 10mV Current 1mA 2mA rating current 3 0A Resolution OVP 10mV V...

Page 5: ...ng from the factory Upon receiving the instrument please unpack and inspect it to check if there is any damage caused during transportation If any sign of damage is found notify the bearer and or the...

Page 6: ...32 to 104 F To operate the instrument exceeding this specific temperature range may cause damage to the circuits of instrument Do not use the instrument in a place where strong magnetic or electric f...

Page 7: ...for value input or setting confirmation 8 F C The knob for switching over coarse and fine adjustment 9 MENU The category of function setting Output OVP OCP Contrast Buzzer Interface PS After switching...

Page 8: ...RAMMABLE POWER SUPPLY USER MANUAL 11 Example If want to set the current as 1 234A first using the F C knob to switch the cursor to 1mA step and adjust the value to 34 then switch the cursor to 100mA s...

Page 9: ...indow will be appeared then using the wheel knob to modify the value and press ENTER to complete the setting Note The system will detect the interface used at present automatically and switch the dete...

Page 10: ...tage to another is done by change AC selects switch The rear panel identifies the line voltage to which the unit was factory set To convert to a different line voltage perform the following procedure...

Page 11: ...e Max measured by the DMM with the knob and press ENTER During the current value input use the PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 17 F C button to switch over the input of 100mA range...

Page 12: ...may leak into the cabinet and cause damage Do not use chemicals containing benzine benzene toluene xylene acetone or similar solvents Do not use abrasive cleaners on any portion of the instrument PSS...

Page 13: ...materials can use the Vr to make adequate adjustment PSS 3203 2005 PROGRAMMABLE POWER SUPPLY USER MANUAL 21 The operation in C C Mode is similar to that in C V Mode The MPU will send 2100 counts 2 1A...