Appendix 

 

Limited Warranty 

B.

Limitation of the Warranty 

 

Duration of 

Gonotec product 

  

Limited Warranty

 

1. 

TO THE EXTENT PERMISSIBLE UNDER THE 
APPLICABLE LOCAL LAWS, NEITHER GONOTEC NOR 
ITS SUPPLIERS SHALL ASSUME ANY ADDITIONAL 
WARRANTY SERVICES OR ACCEPT ANY OTHER 
CONDITIONS, EXPRESS OR IMPLIED, WITH REGARD 
TO THE GONOTEC PRODUCTS. 

 

Software   

 

  90 days

 

Thermistor probe 

 

180 days

 

Osmometer 

 

    1 year

 

 

A.     Extension of the Limited Warranty 

C.   Limitations of Liability 

1. 

Gonotec guarantees the end user that Gonotec products 
shall be free from manufacturing and material defects for 
the above periods of validity from the purchase date. The 
end user must provide proof of the purchase date.

 

1. 

To the extent permissible under the applicable local laws, 
the legal remedies named here shall be the sole and 
exclusive legal remedies available to the customer. 

 

2. 

For software products, Gonotec’s limited warranty applies 
only to the non-execution of programming instructions. 
Gonotec does not guarantee that the operation of a 
product will proceed without errors or interruptions.

 

2. 

TO THE EXTENT PERMISSIBLE UNDER THE 
APPLICABLE LOCAL LAWS AND WITH THE 
EXCEPTION OF THE OBLIGATIONS EXPRESSLY 
NAMED HERE, NEITHER GONOTEC NOR ITS 
SUPPLIERS SHALL BE LIABLE FOR DIRECT OR 
INDIRECT, SPECIFIC, INCIDENTAL OR 
CONSEQUENTIAL LOSSES, WHETHER BASED ON A 
CONTRACT, A TORTIOUS ACT OR ANOTHER LEGAL 
THEORY, AND NOTWITHSTANDING PRIOR 
NOTIFICATION OF THE POSSIBILITY OF SUCH A 
LOSS. 

3. 

Gonotec’s limited warranty applies only to defects that 
arise during normal operation of the product. It does not 
apply under the following conditions:

 

d.  Inadequate servicing or improper modification; 
e. Use of software, interfaces, print media or accessories 

not supported or supplied by Gonotec; or 

f.  Use of the equipment in a manner not covered by the 

product specifications. 

D. Respective 

Jurisdiction 

1.      This warranty statement guarantees the customer  

4. 

For Gonotec osmometers, the use of measuring vessels 
of manufacturers other than those of the measuring 
vessels supplied by Gonotec does not void the customer’s 
warranty claims or any customer support contracts 
between Gonotec and the customer. 

certain legal claims. The customer may have other legal 
claims that go beyond those outlined here.

 

Such claims vary by state in the US, by province in Canada 
and by nation elsewhere in the world. 

2. 

Elements of this warranty statement that conflict with local 
laws can be regarded as amended to comply with the 
applicable laws. For this reason, certain warranty 
exclusions and restrictions outlined here may be of no 
relevance to the customer. In some states of the US, in 
some Canadian provinces and in some countries outside 
North America, for example, the following national laws 
apply:

 

        If, however, the use of measuring vessels from third-party 

providers or the cleaning of recycled measuring vessels 
results in malfunctions or damage to the osmometer or 
thermistor probe, Gonotec shall assess the normal fees 
for the time and material required to repair such 
malfunctions or damage. 

5. 

If Gonotec is notified within the warranty period of a defect 
in a software product, in media or in a thermistor probe 
and if the Gonotec warranty applies to the defect, 
Gonotec shall replace the defective product. If Gonotec is 
notified within the warranty period of a defect in a 
hardware product and if the Gonotec warranty applies to 
the defect, Gonotec shall repair or replace the defective 
product at its discretion.

 

a. 

Exclusion of the fact that the warranty exclusions and 
restrictions named here restrict the legal rights of a 
customer (for example: Great Britain)

 

b. Restriction of the possibilities for manufacturers to 

enforce such warranty exclusions and restrictions 

c.  Granting of additional warranty claims for the customer, 

fixing of the validity period for implied warranty services 
that the manufacturer may not exclude, or nonadmission 
of restrictions relating to the validity period for implied 
warranty services 

6. 

If Gonotec is unable to repair or replace a defective 
product to which the Gonotec warranty applies, Gonotec 
shall refund the purchase price of the product within a 
reasonable period following notification of the respective 
defect. 

3. 

THE FOLLOWING APPLIES TO CONSUMER 
TRANSACTIONS IN AUSTRALIA AND NEW ZEALAND: 
THE CONDITIONS OF THIS WARRANTY STATEMENT 
NEITHER EXCLUDE LEGAL RIGHTS APPLICABLE TO 
THE SALE OF GONOTEC PRODUCTS TO SUCH 
CUSTOMERS NOR REPRESENT A RESTRICTION OR 
AMENDMENT OF SUCH RIGHTS, BUT INSTEAD 
REPRESENT A SUPPLEMENT TO THESE RIGHTS, 
EXCEPT TO THE EXTENT PERMISSIBLE UNDER THE 
LAW. 

7. 

Gonotec is not obligated to repair or replace a product or 
refund its purchase price until the customer returns the 
defective product 

 

to Gonotec. 

8. 

Replacement products may be new or almost new, as 
long as their functionality is at least that of the replaced 
product. 

 

9. 

The Gonotec limited warranty is applicable in all countries 
in which Gonotec sells the applicable product. The 
following countries and regions are exceptions: All 
countries outside the EU. In these countries, the warranty 
is only valid in the country in which the product was 
purchased. Contracts for additional warranty services, 
such as on-site service, may be available from an 
authorized Gonotec sales partner.

 

 

50   |   

Appendix

 

 

Summary of Contents for Osmomat Auto

Page 1: ...www gonotec com User Guide Osmolality Measurement in medical and pharmaceutical field Cryoscopic Osmometer OSMOMAT auto...

Page 2: ...example by improperly using measuring vessels This symbol warns of the danger of damaging the unit or the measurement system for example as a result of improper servicing Note or tip Subject to errors...

Page 3: ...Overview of Display and Connectors 11 2 2 Power Supply 12 2 3 Dimensions and Weight 12 2 4 Sample Holder 13 3 Setup and Initial Operation 14 3 1 Safety and Handling Information 15 3 2 Known Risks Ass...

Page 4: ...lity Control of the OSMOMAT auto 35 10 5 Settings 36 10 6 Printer Maintenance 39 10 7 Replacing the Cleaning Paper 40 10 8 Replacing a Defective Initiation Needle 42 10 9 Replacing a Defective Power F...

Page 5: ...ssification of the IVD 49 EC Compliance Statement OSMOMAT auto 49 Provisions of Certification 49 Limited Warranty 50 Returning Parts for Warranty 51 Repair or Credit 51 Before Calling Gonotec 51 Techn...

Page 6: ...per roll 39 Fig 8 Replacing the ribbon 40 Fig 9 Replacing a Initiation Needle 42 Fig 10 Power switch 43 List of Tables Table 1 Malfunction of the elevator track lower cooling system printer component...

Page 7: ...proven measurement principle of the Osmomat 030 The system developed by Gonotec for initiating crystallization by injecting ice crystals is also used here The sample data can be entered via the keypad...

Page 8: ...freezing point of 1 858 C That means that one mol of a given non dissociated substance 6 023 x 1023 parts diluted in one kilogram of water lowers the freezing point of a solution by 1 858 C The follow...

Page 9: ...ing point If the sample consists of water solvent equilibrium is achieved as long as the sample contains water and ice The temperature remains constant because further heat removal does not result in...

Page 10: ...ack to Gonotec for repairs or servicing This will save you the time and money needed to find equally suitable packaging 1 6 Packaging Contents Check to make sure the contents of your shipment are comp...

Page 11: ...verview of Display and Connectors LCD display Keypad Matrix printer cover Elevator with Paper feed Cleaning paper holder Lower front plate with Transport fastener for lower cooling system Thermistor F...

Page 12: ...Fus o Serial output Barcode reader Serial output RS232 Housing fan with cover 1 0 FUSE Potentiometer for service settings Fig 3 Rear view of the OSMOMAT auto 2 2 Power Supply The standard model is op...

Page 13: ...e sample holder from 1 through 20 Position 0 is reserved for the initialization sample with distilled water Refer to section 5 Calibration of the OSMOMAT auto Initialization sample 20 sample spaces Th...

Page 14: ...that the cable s green yellow wire be connected to the safety grounding It is also important to ensure that the voltage indicated on the name plate matches that of your electricity network Incorrect v...

Page 15: ...ls on the unit and its name plate correspond to the requirements of the following standards DIN EN 61010 1 DIN EN 375 and DIN EN 980 harmonized standard for medical devices according to 3 No 17 of the...

Page 16: ...points are selected via the arrow keys and the Esc key The number keys and the Ctrl key are used for data entry 4 1 Display and Keypad Overview Selection keys Cleaning paper feed Select print options...

Page 17: ...rn from the submenu directly to the initial display The functions and option elements are described in the individual chapters Measurements and Settings Select sample to perform sample measurements ca...

Page 18: ...ample holder to prevent premature evaporation of the samples The sample cover reduces the risk of premature evaporation of the samples However it does not protect the samples from leakage To perform t...

Page 19: ...is retained even after the unit is switched off and restarted but lost after new initialization Note Prior to the calibration procedure switch the printer on to document the calibration results Subseq...

Page 20: ...ve 500 mOsmol kg are possible for c2 If c1 300 mOsmol kg all calibration points above 600 mOsmol kg are possible for c2 If c1 2000 mOsmol kg 3000 mOsmol kg are possible for c2 The following display sa...

Page 21: ...a measuring vessel with distilled water If position 0 is not filled there is no measured value for the first sample The sample cover is then placed on the sample holder to prevent premature evaporatio...

Page 22: ...are comprised of a system defined Ch batch number and Pat patient number measured value in osmol or error message as plain text under Status spon crystallization no crystallization and optionally of s...

Page 23: ...ure that position 0 is always filled with a measuring vessel with distilled water If position 0 is not filled there is no measured value for the first sample Be sure to identify samples uniquely The s...

Page 24: ...the Print Mode button to switch the print functions on and off and select them Press the button until the desired print function is reached It is signalized by a lit LED OFF Printer is off Measurement...

Page 25: ...again to return to the initial display Searching for Batch and Sample Results You can search for sample results in the memory by batch Select sample memory look at charge in the initial display Confir...

Page 26: ...ort Provides quick printout of complete batch of the displayed sample Charge long Provides long printout of complete batch of the displayed sample Deleting Data You can delete data from the memory by...

Page 27: ...utine to check the memory capacity for measurement data prior to each measurement series The memory manager outputs a warning on the display when the memory capacity is less than 20 units of measureme...

Page 28: ...ile measuring the sample solution The OSMOMAT auto monitors temperature changes during the undercooling phase If crystallization begins prematurely before the undercooling temperature of 7 C is reache...

Page 29: ...ch crystallization is initiated however crystallization will not start despite the very effective method of initiation crystallization via the injection of ice crystals This condition is further exace...

Page 30: ...ld a paper towel underneath the thermistor probe The bore can first be rinsed using a spray bottle of water to clean out sample residues which can rub off and accumulate on the interior surface over t...

Page 31: ...es too long measurement interrupts No reading Error message Incorrect reading Corrosion Ventilator dusty Incorrect adjusted lower cooling system Peltier element defective Use fine sandpaper to clean t...

Page 32: ...or message Peltier element ruined e g by liquid deposits Corrosion Incorrect adjusted upper cooling system Bar of needle too short or too long Photoelectric beam for motor control defective or incorre...

Page 33: ...oosely on the thermistor probe Defective When lowered into the lower cooling system the thermistor probe moves outside the center of the solution Incorrect reading Incorrect or no reading Incorrect re...

Page 34: ...length Debur tip of needle Straighten or replace needle Check upper cooling system component group Rear of unit power switch Power supply Fuses in power switch blow out when unit is switched on It do...

Page 35: ...ce with relevant accident prevention guidelines 10 3 Measurement Checks 11 of Medical Devices Operator Ordinance The OSMOMAT auto is not listed in Annex 2 of the Medical Devices Operator Ordinance No...

Page 36: ...to accept the change Select insert date and confirm with OK to set the date The cursor blinks in the date Enter the date in the format Day Month Year using the numbers 0 through 9 The cursor automatic...

Page 37: ...needle for example To check the initiation function select adjust actuate cryst motor in the initial display Confirm with OK to rotate the initiation needle one time New Initialization Reinitialize t...

Page 38: ...s user guide Select adjust thermistor probe in the initial display Confirm with OK to initiate start up or shutdown of the thermistor probe Start up and shutdown are controlled by a stepper motor The...

Page 39: ...e printing device 1 Turn the printer to its bottom position Remove the empty roll core from the paper tray 2 Insert a new paper roll Pay attention to the feed direction of the paper roll Fig 7 Correct...

Page 40: ...on Tighten the ribbon by twisting the knob again 5 Press and hold the Paper Feed button until approx 2 cm of the printer paper is protruding from the housing and then close the door 10 7 Replacing the...

Page 41: ...the new roll and reattach the cover 3 Run the paper below the stainless steel plate with a hole Press the Paper Feed button and run the paper to the drive rollers for the paper feed 4 Press and hold t...

Page 42: ...ntaminated especially the initiation needle Risk of injury from the tip of the needle In the event of injury from the tip of the needle always consult a doctor to check whether any infection with a pa...

Page 43: ...diameter 0 6mm 10 9 Replacing a Defective Power Fuse Before replacing a defective power fuse unplug the unit from the power supply Risk of electric shock To replace the fuses use a small screwdriver...

Page 44: ...0 9 0010 pdf Specification The conic shape of the measuring vessel matches that of the lower cooling system This ensures a secure fit a high standard of centricity for the measuring vessel in the lowe...

Page 45: ...Declaration Calibration and Reference Material Gonotec GmbH GSG Hof Reuchlinstr 10 11 10553 Berlin Germany We hereby declare that the calibration standard for Osmomat 010 030 auto 300 and 850 mOsmol...

Page 46: ...he package insert of each batch 11 4 Safety and Handling Information Calibration and reference materials are not dangerous according to EC Directive 67 548 EEC Poison class Switzerland F no poison cla...

Page 47: ...ing osmolality is an indication that the shelf life has elapsed 11 6 Use of Other Calibration Solutions Osmolality Sodium chloride concentration Freezing point depression mOsmol kg H Table 5 NaCl solu...

Page 48: ...9 2000 Calibration standard 2000 mOsmol kg ampoules of 1ml each 10 30 9 1010 Printer paper roll for OSMOMAT 030 D auto 8 30 9 1020 Endless ribbon cassette for OSMOMAT 030 D auto 1 35 9 1030 Roll of cl...

Page 49: ...mbH GSG Hof Reuchlinstr 10 11 10553 Berlin Germany We hereby declare that the cryoscopic osmometer OSMOMAT auto complies with Directive 98 79 EEC Compliance is declared per Annex III of the Directive...

Page 50: ...ions outlined here may be of no relevance to the customer In some states of the US in some Canadian provinces and in some countries outside North America for example the following national laws apply...

Page 51: ...ks manuals etc 6 Return the equipment in its original packaging If you no longer have the original packaging you may purchase replacement packaging from Gonotec Before Calling Gonotec Note When callin...

Page 52: ...and DTR signals are currently supported We recommend use of a null modem cable with the following bridges 6 4 1 and 7 8 The data is consecutively sent to the built in printer and serial interface If...

Page 53: ...on Crystallization resolution By injecting the sample with ice crystals Error message Printed in plain text Cooling RS output Using two independent peltier cooling systems with heat dissipation by air...

Page 54: ...s backside and remove the red marked transportation locks with the socket wrench hexagon socket Transportation lock Please keep this instruction for an eventual return of the instrument as this allows...

Reviews: