background image

3

UNDERSTANDING TOLERANCE ADJUSTMENT

 The base side tightness (male) can be adjusted with the provided shims 

to add or remove tolerance between the male and female sides of the 

QR. 

Each shim is 0.05mm in thickness. To achive the perfect fitment add or 

remove one shim at a time until desired fit is found. 

Too many shims will make the fitment too tight and will cause lack of 

engagement of the QR retaining pins, causing a unreliable connection. 

Too few shims can lead to unwanted lateral movement.

WARNING! Test fitment for reliable connection before use. 

TOLERANCE ADJUSTMENT CAP

M3 x 6mm SHIM SCREWS

TOLERANCE SHIMS

QRS-1 BASE SIDE