WIRING DIAGRAMS
(
AND
)
BLOCK MODE
POWER MODE
:
BUS
BUS
BUS
BUS
D2
D1
D2L-G2+
OUT
IN
RD-G2+ (2)
FA
PL
B
U
S
B
U
S
ART 4/G2+
Master
APARTMENT 1
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 2
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 31
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 32
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
B
U
S
B
U
S
BUS
BUS
BUS
BUS
D2
D1
D2L-G2+
B
U
S
B
U
S
B
U
S
B
U
S
End of
line
BUS
BUS
BUS
BUS
D2
D1
D2L-G2+
OFF
End of
line
*
( )
B
U
S
B
U
S
ART 4/G2+
Master
APARTMENT 33
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 34
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 63
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 64
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
B
U
S
B
U
S
BUS
BUS
BUS
BUS
D2
D1
D2L-G2+
B
U
S
B
U
S
B
U
S
B
U
S
ON
End of
line
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
L
N
OUT
IN
RD-G2+ (3)
FA
PL
BUS
BUS
BUS
BUS
D2
D1
D2L-G2+
OFF
End of
line
*
( )
B
U
S
B
U
S
ART 4/G2+
Master
APARTMENT 65
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 66
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 95
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 96
**
( )
1 ( )
B
U
S
B
U
S
BUS
BUS
BUS
BUS
D2
D1
D2L-G2+
B
U
S
B
U
S
B
U
S
B
U
S
ON
End of
line
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
L
N
Apartments 1-32
Apartments 33-64
Apartments 65-96
Technical room
Technical room
OFF
End of
line
OUT
IN
RD-G2+ (1)
FA
PL
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
L
N
Technical room
OUT
IN
RD-G2+ (4)
FA
PL
BUS
BUS
BUS
BUS
D2
D1
D2L-G2+
OFF
End of
line
*
( )
B
U
S
B
U
S
ART 4/G2+
Master
APARTMENT 97
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 98
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 127
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
ART 4/G2+
Master
APARTMENT 128
**
( )
1 ( )
ON
1
2
3
4
5
6
7
8
B
U
S
B
U
S
BUS
BUS
BUS
BUS
D2
D1
D2L-G2+
B
U
S
B
U
S
B
U
S
B
U
S
ON
End of
line
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
L
N
Apartments
-128
97
Technical room
BUILDING 2
ON
1
2
3
4
5
6
7
8
Set the End of line jumper on the last
distributor to ON, set all other
intermediate distributors to OFF.
Configur the end of line in
e
the last monitor
.
/ RD-G2+
Dip 8 to On.
**
( )
*
( )
Interior door panels
(see page 36-38).
To next building.
(In the last building
“
RD-G2+
as block mode
”
Dip 8 to On).
( )
1 Important:
For description, installation, configuration and programming of door panels and monitors, see the corresponding manuals.
Power mode
**
( )
Power mode
**
( )
Power mode
**
( )
Power mode
1
2
3
ON
DIP
4
5
6
7
8
**
( )
1
2
3
ON
DIP
4
5
6
7
8
1
2
3
ON
DIP
4
5
6
7
8
Block mode
1
2
3
ON
DIP
4
5
6
7
8
**
( )
BUILDING 2
Note:
p g
, see a es 6 & 8.
Distanc s
e and cross-sections
RD-G2
+
DIGIT
AL REPEA
TER
Video installation with general coded door panels, buildings of 128 monitors (ART 4 / ART 7H / ART 7W), 1 RD-G2+
“
”
& 3RD-G2+
“
”
.
block mode
power mode
**
( )
1 ( )
**
( )
1 ( )
From building 1
(see page
).
33
OFF