The DIP switches of the RD-G2
module enable con
fi
guration of one of the 3 operating modes
+
, building address
number
“
”
and end of line
block mode
.
Description of the DIP switches:
1
2
3
ON
DIP
4
5
6
Con
fi
gur
:
ing the operation mode
Ampli
fi
er mode:
DIP switches: 1 set to ON and 2 set to OFF.
Power mode:
DIP switches: 1 set to OFF and 2 set to ON.
Block mode:
DIP switches
and 2 set to
N.
: 1
O
No function.
Con
fi
guration of the address number in the RD-G2+ module installed in "block mode":
*
( )
Factory setting.
7
8
1
2
3
ON
DIP
4
5
6
7
8
1
2
3
ON
DIP
4
5
6
7
8
1
2
3
ON
DIP
4
5
6
7
8
Dip switches 3 to 7 of the RD-G2+ module allow us to set the address (building) of the RD-G2+ "block mode" (address 1 to
32).
The DIP switches in the OFF position have zero value. In the ON position, they are assigned the values from the table
below. The address code of the RD-G2+ module will be equal to the sum of the values of the switches set to ON.
Important:
- Select a di
ff
erent address number for each RD-G2+ module in "block mode".
Dip switches 3 4 5 6 7
:
ON
: 1 2 4 8 16
value
Tabl
val
e of
ues
1
2
3
ON
Example: 1+ 0+4 0+0 5
+
=
4
5
6
7
8
Important:
-Address 1: (Dip3 set to ON & Dip4-Dip7 set to OFF)
-Address 32 (Dip3 - Dip7 set to OFF).
Con
fi
gur
:
ing the end of line on the RD-G2+ module
1
2
3
ON
DIP
4
5
6
7
8
Interruptor 8 a ON
1
2
3
ON
DIP
4
5
6
7
8
Interruptor 8 a OFF
DIP switch 8 of the RD-G2+ activates the end-of-line resistance in the ON position. Activate it in monitors where the bus
cable ends. Deactivate it only in intermediate monitors.
DIP
*
( )
The DIP switches 1 and 2 of the RD-G2+ module allow us to con
fi
gure between one of the 3 operating modes.