4
DESCRIPTION
ART 7 /G2+ MONITOR
H
A.
Speaker.
B.
Notification icons:
Power on indicator.
Do not disturb.
Auxiliary relay activated.
Door opening.
New image/video.
C.
Hidden button indicator LEDs
:
To access the main menu (monitor in standby),
press either of the 2 buttons
located above
/
the raised dots for the visually impaired (see p. )
6 .
In call/ communication: press button to start or end
the communication.
In call/ communication: one pres will activate the
lock release for 3 seconds.
In call/communication: an LED shows the location of
each of the hidden buttons.
The function of each hidden button is shown on the
monitor screen with an icon located just above
each button (see pp. -2 ).
6 0
D.
.
Raised dots for the visually impaired
In standby:
Above the raised dots for the visually impaired /
are
the buttons that access the main menu.
In call:
Above this raised dot is the 'Start/end communication'
button
.
Above this raised dot is the 'Door opening' button
.
E.
7” TFT colour screen.
F.
Microphone.
G.
Communication with hearing aids (Art 7H/G2+).
Set the hearing aid switch to the T position, see page .
5
H.
Micro SD card slot (not included).
Type: MicroSD Class 10 from 4GB to 128GB.
I.
Wall mounting connector fixing (x4).
J.
Configuration switches.
K.
Installation terminals.
*
A
E
B
D
G
H
I
J
K
I
I
I
K
SA
GND
HZ
HZ
B
U
S
IN
ON
1
2
3
4
5
6
7
8
B
U
S
O
U
T
DIP 1 to 7
Monitor address
SA
GND
HZ
HZ
BUS
IN
BUS
OUT
DIP 8
EOL resistor
OFF = 0
ON = 1
128
codes
12210702 V01
MONITOR 7” ART 7H/G2+
GOLMAR S.A.
C/ Silici, 13
08940 - SPAIN
WARNING
TO PREVENT FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS
DEVICE TO RAIN OR MOISTURE
CAUTION
TO PREVENT ELECTRIC SHOCK,
DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL
MADE IN CHINA
128
codes
*
Hidden button
pressing area
C
F