Gas Conversion
17
9.
Gas Conversion
1.
a. (MTHVFG02) Rotate the thermostat knob in
alignment with the control panel cut-out then
undo the screws holding in the control panel and
remove. Do
NOT
remove or loosen the
thermostat knob when taking off the control
panel as this will cause the fryer temperature to
go out of calibration and will need to be re-
adjusted if removed.
b. (MTHRS205) Pull off the thermostat knob from
the bezel and then undo the fixing screws holding
the thermostat to the control panel.
2.
Undo the manifold union. Undo the thermopile
wires and pilot tubes from the gas control for
easier access.
3.
Remove the pilot assembly bracket from the
burner and replace the pilot injector with the
new appropriate type.
4.
Undo the burner holding screws then the burner
can be dislodged by unhooking the rear bracket.
5.
Remove the union and fit it on the new
appropriate burner. Apply new thread sealant
and compound on the union before fitting.
6.
Re-attach the appropriate burner assembly to
the tank and manifold in reverse order.
9.1
Commissioning
1.
Check all work for leakage using appropriate gas
detecting equipment.
2.
Refer to section 4.6 Commissioning for a check list.
3.
Replace the rating plate and any markings associated with the gas type with the appropriate
type.
WARNING
Gas conversion procedures should only be performed by an authorized Goldstein Eswood
service agent or qualified personnel. Unauthorized and unqualified personnel will void the
warranty. Gas isolator MUST be turned off before commencing any service work.
Knob Alignment
Img 5. a
–
MTHVFG02 thermostat
Img 5. b
–
MTHRS205 thermostat
Pilot Holding Screws
Burner
Holding
Screws
Burner
Bracket Clip
ATTENTION
Gas conversion is not complete until the appliance has been re-commissioned. Please refer to
the Installation section 5.5 Commissioning of this manual for details.
Pilot Adjustment
Img 6