(2) CHECKOUT PROCEDURES FOR RELAY.
- PROBLEM (A) -
FAN motor and oven lamp turn on without touching
START key when the door is closed.
Remove the mate connector of I/O
CON from the circuit board.
Does the unit still operate?
GOOD
Replace the
circuit board
Replace
RELAY1
- PROBLEM (B) -
FAN motor and oven lamp turn on When the door is
closed and START key is touched.
Measure the voltage at pin NO.
35 of U01 or 7of U03
Voltage reading: 0 Vdc
Replace the
circuit board
Defective
RELAY1 or poor
connection of
RELAY1
Defective
RELAY1
Replace
RELAY1 or correct
the connection.
NO
NO
YES
YES
NO
NO
YES
YES
GOOD
Summary of Contents for MV-1525B
Page 37: ...8 1 EXPLODED VIEW DOOR PARTS 1000 1008 1002 1001 1006 1005 1007 1004 1003 W105 ...
Page 38: ...8 2 CONTROLLER PARTS 2000 2005 2001 2003 2002 2004 2007 W083 2010 ...
Page 40: ...8 4 LATCH BOARD PARTS 4001 4002 4001 4003 4000 W030 ...
Page 44: ...8 15 SCHEMATIC DIAGRAM OF P C B ...
Page 45: ...8 16 PRINTED CIRCUIT BOARD ...