background image

AquaRite Long Life 

Electrolytic Chlorine Generator 

CONTROLS BACTERIA AND ALGAE 

In Residential Swimming Pools and Spas 

 

READ THIS LABEL AND OPERATION MANUAL BEFORE 
USING. PRECAUTION: 

A maximum of 95,000 Litres (25,000 Gallons) of water can be treated with one 
AquaRite Long Life Electrolytic Chlorine Generator unit. Operating the AquaRite Long Life 
Electrolytic Chlorine Generator without water flow through the AquaRite Long Life 
Electrolytic Chlorine Generator cell can cause a build-up of flammable gases which can result 
in fire or explosion .The AquaRite Long Life Electrolytic Chlorine Generator protects itself 
against this condition via the FLO sensor by cutting off the power to the AquaRite Long Life 
Electrolytic Chlorine Generator cell whenever flow is not detected. The AquaRite Long Life 
Electrolytic Chlorine Generator MUST be wired to the same circuit as the filter pump. This 
ensures that the AquaRite Long Life Electrolytic Chlorine Generator will only generate 
chlorine when the filter pump is providing flow. The AquaRite Long Life Electrolytic 
Chlorine Generator generates a maximum output of hypochlorous acid equivalent to 0.45 kg 
of chlorine per day. Do not use this device with bromide products. 

 

 

KEEP OUT OF REACH OF CHILDREN 

 

NOTICE TO USER: 

This pest control product is to be used only in accordance with 

the directions on the label. It is an offence under the Pest Control Products Act to use 
this product in a way that is inconsistent with the directions on the label. 

 

SWITCH: 

(The switch is ignored when operation is Remotely Controlled) 

Super-Chlorinate: Chlorine is produced at the maximum rate, regardless of the “Desired 
Output %” dial for the remainder of the current filtering period (maximum 24 hours). 
Auto: Chlorine is produced at the rate determined by the “Desired Output %” dial. 
Off: Chlorine production is turned OFF. The power is controlled by the filter pump timer. 

 

CHLORINE LEVEL DIAL: 

(The Desired Output dial is ignored when operation is Remotely Controlled) 

Adjust the “Desired Output %” dial to control the amount of chlorine produced. 
Periodically check the pool chlorine level and adjust the dial up or down as required. 
For swimming pools, a minimum of 1 ppm of free available chlorine must be 
maintained. 
For Spas, a minimum of 3 ppm of free available chlorine must be maintained. 

 

 

LCD DISPLAY: 

Displays salt level in ppm (parts per million). 

Summary of Contents for AquaRite Long Life

Page 1: ...2019 2660 2019 10 16 Part No AQR940 Electrolytic Chlorine Generator DOMESTIC READ THE LABEL AND MANUAL BEFORE USING REGISTRATION NUMBER 28325 5 PEST CONTROLS PRODUCT ACT...

Page 2: ...acement cell for the AquaRite Long Life This cell must only be used on this model of chlorine generating device Read the label the Installation and Operation Manual of the AquaRite Long Life Electroly...

Page 3: ...or generates a maximum output of hypochlorous acid equivalent to 0 45 kg of chlorine per day Do not use this device with bromide products KEEP OUT OF REACH OF CHILDREN NOTICE TO USER This pest control...

Page 4: ...wing through the AquaRite Long Life Electrolytic Chlorine Generator cell Chlorine Check Salt Salt is below 2600 ppm AquaRite Long Life Electrolytic Chlorine Generator is working at reduced efficiency...

Page 5: ...ALGAE in Residential Swimming Pools and Spas DOMESTIC READ THE LABEL AND MANUAL BEFORE USING REGISTRATION NUMBER 28325 5 PEST CONTROL PRODUCTS ACT Goldline Controls Inc A Hayward Company 61 Whitecap D...

Page 6: ...his pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Products Act to use this product in a way that is inconsistent with t...

Page 7: ...Table of Contents OPERATION General 1 Water Chemistry 1 Controls 6 Maintenance 8 INSTALLATION Mounting 9 Plumbing 10 Wiring 11 TROUBLESHOOTING Troubleshooting 14 WARRANTY Warranty 16...

Page 8: ...quired to properly sanitize a pool varies due to bather load rainfall temperature and the pool s cleanliness Water Chemistry The table below summarizes the recommended water parameters The only specia...

Page 9: ...he pool water balance Your water is properly balanced if the Si is 0 2 If the Si is below 0 2 the water is corrosive and plaster pool walls will be dissolved into the water If the Si is above 0 2 scal...

Page 10: ...arily to the addition of water because of splashing backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl sal...

Page 11: ...4 Diagram...

Page 12: ...5 Diagram...

Page 13: ...rination See description above REMOTELY CONTROLLED When illuminated indicates that a remote pool automation control Goldline Aqua Logic Pentair Intellitouch Polaris Eos etc is controlling the AquaRite...

Page 14: ...7 Generator has stopped producing chlorine Inspect clean or replace if necessary...

Page 15: ...to generate enoughchlorine To find the optimum Desired Output setting start at approximately 50 Test the chlorine level every few days and adjust the dial up or down accordingly It usually takes 2 3 a...

Page 16: ...hat a buildup on the AquaRite Long Life Electrolytic Chlorine Generator cell indicates that there is an unusually high calcium level in the pool old pool water is usually the cause If this is not corr...

Page 17: ...1 Spring Start up DO NOT turn the AquaRite Long Life Electrolytic Chlorine Generator on until the pool water chemistry has been brought to the proper levels This information can be found on page 1...

Page 18: ...Life Electrolytic Chlorine Generator system Mounting the AquaRite Long Life Electrolytic Chlorine Generator Control The AquaRite Long Life Electrolytic Chlorine Generator is contained in a raintight...

Page 19: ...enerator cell Configurations 2 and 3 allow for chlorination of both the pool and spa during spa spillover operation but prevent over chlorination of the spa during spa only operation Never use configu...

Page 20: ...ator shall be connected to a circuit protected by a class A ground fault interrupter Be sure to connect the ground wire to the green ground screw terminal located on the bottom of the enclosure Diagra...

Page 21: ...52 meters 500 feet apart Any outdoor rated 4 conductor cable can be used Refer to each manufacturer s instructions and the wiring diagrams below for proper wiring connection to the AquaRite Long Life...

Page 22: ...Polaris Attach wires to proper screw terminals as shown below Note that screw terminal 1 is marked on the Polaris PCB Diagram 13...

Page 23: ...s not pushed for 30 seconds the display will revert back to the standard salt display Common Problems and Solutions 1 Power LED not on Check to make sure either 120VAC or 240VAC input power is connect...

Page 24: ...ted the cell may be worn and need replacement 8 Possible causes of little or no free chlorine residual AquaRite Long Life Electrolytic Chlorine Generator switch in OFF position Desired Output adjustme...

Page 25: ...pool automation or chlorination product or part with a part number other than AQRITE AQ TROL AQ LOGIC AQL P AQL PS or AQL CL to be free from defects in material or workmanship under normal use and se...

Page 26: ...Diagram Goldline Controls Inc A Hayward Company N Kingstown RI 02852 USA 888 921 POOL 7665 092009 Copyright 2004 Goldline Controls Inc...

Page 27: ......

Reviews: