![Golden Avenger GA541 Owner'S Manual Download Page 32](http://html.mh-extra.com/html/golden/avenger-ga541/avenger-ga541_owners-manual_2240469032.webp)
32
Possible solutions:
Recharge your batteries.
If the problem persists, have an authorized Golden provider “load test” the
batteries to verify they are not damaged.
If the problem persists, assure your battery charger is operating properly.
Resetting the Main Circuit Breaker
If the main circuit breaker trips as a result of “run-down” batteries or because of a
temporary overload, reset the circuit breaker using the following directions:
1. Wait 5 minutes to allow the motor and electronics board to cool, or return to
“normal” operating temperature.
2. Press in on the main circuit breaker reset button.
BE SURE YOU REMOVE THE KEY FROM THE KEY RECEPTACLE
BEFORE RESETTING YOUR SCOOTER.
If the main circuit breaker continues to trip, there is an underlying electrical
fault that needs professional attention. Please contact your local Golden Technologies
Provider.
Do not reset your main circuit breaker repeatedly. You must correct the underlying
problem. Failure to correct the problem could cause injury or damage and will void the warranty.
XI. CARE AND MAINTENANCE
This is the “LED” light that will flash
in the event of a problem.
Main Circuit Breaker
Circuit Breaker
Found on the rear
of the unit next to
the freewheel
brake release.
The 50-amp circuit breaker and exposed reset button
are located under the battery cover. The button is visible
through the battery cover. If your
fails to
operate, your main circuit breaker may have tripped.
DO NOT ATTEMPT ELECTRICAL REPAIRS.
CONSULT GOLDEN TECHNOLOGIES OR YOUR AUTHORIZED
GOLDEN PROVIDER.
Possible causes for the main circuit breaker to trip:
“Run-down” batteries.
Over exerting the motor.
Summary of Contents for Avenger GA541