IF YOUR DESIRED INSTALLATION DOES NOT MEET THE ABOVE REQUIREMENTS, CONTACT
GOLDEN BLOUNT, INC. TO VERIFY IF DESIRED INSTALLATION CAN BE CONGIFURED WITH
OTHER APPROVED POWER VENT EXHAUST FAN. 1-800-833-1134
WARNING:
This gas appliance must not be connected to a chimney flue serving a separate
solid-fuel burning appliance.
Note: a draft hood is installed and is in the same atmospheric pressure zone as the combustion air
inlet to the appliance and is located so that the relief opening is accessible for checking vent
operation.
Minimum Vent Length ---------5
'
Maximum Vertical Run --------50
'
Maximum Horizontal Run -----50
'
Maximum 45 Deg. Elbows ----4 ea.
Maximum 90 Deg. Elbow ------3 ea.