(d) Activate the transmitter
S e l e c t t h e o p e r a t i n g
frequency and the output
level as described previously
in this manual
(e) The line is now energized
Using INDUCTIVE Energizing
Another common method to energize a
line is by induction When the signal jacks of the Model
X are not
being used the transmitter case emits an INDUCTIVE field which when
placed over the target line will energize it This method requires none
of the underground line to be exposed However INDUCTIVE mode is
best used on isolated lines and away from areas congested with many
services and metallic objects
(a) Make sure both SIGNAL jacks are empty and activate the
transmitter
(b) Select the operating frequency and the output level as described
previously in this manual
(c) Close the latch covers on the case and position the case over the
underground line so that the hinge of the case is roughly in line
with the target line Also it is recommended that the transmitter
case be turned so that the hinge axis is offset about ° from the
supposed direction of the underground line
(d) The line is now energized
PASSIVE Energizing
Finally the user should be aware that some lines
are “always” energized An example of this kind of line is a power line
Power lines that are actively in service constantly carry AC current This
current is typically at a frequency of
Hz with harmonic components
at multiples of
Hz (i e
Hz
Hz
Hz etc ) In Europe this