GENERAL INSTRUCTIONS 
 

• It is illegal for persons other than those authorised by legislation to work on the fixed wiring 
of any electrical installation. 
• All installations must be in accordance with the local Electrical Wiring Regulations and 
Wiring Rules. 
• Means for  disconnection  must be  incorporated  in  the fixed  wiring  in accordance  with  the  wiring 
rules. 
• This heater must not be mounted immediately below or in front of a socket outlet. 
• The heater must be installed a minimum of 1.85 metres from the floor, a minimum of 300mm from 
the nearest side to an adjacent wall and a minimum of 300mm from the ceiling to the top face of 
the heater (see Fig. 5). The heater must not be mounted to the ceiling or be built in/recessed. 
• The appliance is to be installed so that switches and other controls cannot be touched by 
a person in the bath or shower. 
• The appliance must be mounted in such a position that doors or other moving objects will 
not obstruct the heater. 
• The appliance must be mounted in such a position that curtains and other combustible materials 
are kept well clear. 
 
 
 

WIRING AND FIXING TO WALL 
 

•Select a location for mounting of the heater in accordance with the GENERAL INSTRUCTIONS. 
•The heater must be connected by permanent wiring within the wall cavity from an isolating 
•Switch.  
•Unpack carefully. Make sure to discard of all packaging and to keep the mounting screw kit. 
•Disassemble the lid from the wall mount/connection box(see Fig.1). 
•Turn the heater 90º to enable it vertical with its bracket(see Fig.2).    
•Choose carefully a place suitable for wall mounting and drill two holes, then fix the bracket of the 
heater to the wall using the two plastic plugs and screws supplied(See Fig. 3). 
•After ensuring that the power supply matches that indicated on the rating label on the heater, re-fit 
the  wall  mount/connection  box  cover  and  position  the  angle  of  the  heater  to  your  personal 
liking(see Fig. 4). 
 
 

INSTALLATION INSTRUCTIONS 

Summary of Contents for GBR200

Page 1: ...For models GBR200 1500W BATHROOM HEATER OPERATING INSTRUCTIONS ...

Page 2: ...er socket by pulling cord always grip plug 16 Always unplug appliance when not in use 17 The heater must not be located immediately below a socket outlet 18 Do not twist kink or wrap the cord around the appliance as this may cause the insulation to weaken and split Always ensure that all cord has been removed from any cord storage area and is unrolled before use 19 This appliance is not intended f...

Page 3: ...be mounted in such a position that doors or other moving objects will not obstruct the heater The appliance must be mounted in such a position that curtains and other combustible materials are kept well clear WIRING AND FIXING TO WALL Select a location for mounting of the heater in accordance with the GENERAL INSTRUCTIONS The heater must be connected by permanent wiring within the wall cavity from...

Page 4: ...INSTALLATION INSTRUCTIONS Fig 1 4 Fig 5 1850mm Min 300mm Min 300mm ...

Page 5: ... grills Be careful not to touch elements Use a cloth with a stainless steel cleaner to clean the exterior of the heater Do not use abrasive cleaning products on this appliance Ensure the heater is dry before turning the power supply back on to the heater Do not attempt to repair or adjust any electrical or mechanical functions on this unit Doing so will void the warranty Contact a qualified electr...

Page 6: ...he time of purchase It is in your interest to make sure this is done If the product is to be replaced cannot be repaired then that replacement will be of the same or similar product or accessory excluding packaging instruction card etc Where a replacement product is supplied this shall be guaranteed for the balance of the original warranty period Any model that is no longer available will be repla...

Reviews: