Installing your Appliance

INSTALLATION

Select a location for mounting of the heater in accordance with the installation instructions

The heater must be connected by permanent wiring within the wall cavity from an isolating
switch.

Ingress Protection (IP):

Bathrooms are divided into four zones based on the levels of

perceived risk within each area. The measurements are taken from the fixed plumbing
connection (water source) and each zone has specific requirements regarding the electrical
equipment that can be used within it.

Goldair Bathroom heaters are rated IPX0 so must

be installed in Zone 3.

The Wall Mounting Base should be positioned as shown in Figure 1.

The wiring within the wall cavity can be terminated into the respective terminals marked L

and N on the wall mounting base. (See Figure 3a).

The Wall Mounting Base must be secured with all four screw fixing points.

Securely fix the Wall Mounting Base to the wall surface with the screws and wall plugs

supplied. (See Figure3b).

The Wall Mounting Base can be used with or without a flush box (Cat144) in the wall
cavity. When using a flush box it should be located directly behind the Wall Mounting Base
connector block.

Fit the heater to the wall mounting base by ensuring the 4 hooks on the wall mounting
base have engaged with the mounting apertures of the heater. Slide the heater down to
lock it into place. The electrical connection is automatically made during this step.

The heater must be locked in place on the Wall Mounting Base for safe operation.

To check the heater is fully locked to the mounting base, attempt to gently slide the heater
upwards. It should be securely held in position.

To remove the heater from the Wall Mounting Base insert a blade screwdriver into the
hole located below the middle of the outlet grille. Rotate the screwdriver until the clip
releases. Then while holding the heater, gently push up with the screwdriver sliding the
heater off the Wall Mounting Base. (See Figure 2.)

Please refer to your user manual for operating instructions, further information or trouble 
shooting before you call the Customer Service number listed within the user manual.

Summary of Contents for 3508W

Page 1: ...Operating Instructions 2400W Bathroom Wall Fan Heater Model 3508W GBH100 GBH250 GBH300...

Page 2: ...activate the safety device permanently disabling the unit WARNING Do not use this appliance in small rooms when they are occupied by persons not capable of leaving the room on their own unless consta...

Page 3: ...nce has been unpacked check it for transport damage and ensure all parts have been delivered If parts are missing or the appliance has been damaged contact the Customer Services Team Do not use if the...

Page 4: ...Components Wall Mounting Plate x 1 Screw Pack Screw x 4 Wall Plug x 4 Main Unit x1 3508W GBH100 GBH250 GBH300...

Page 5: ...iring rules CAUTION Do not mount directly under or above an electrical power socket It is recommended to install the heater to the side of any power socket CAUTION The appliance is to be installed so...

Page 6: ...ied See Figure3b The Wall Mounting Base can be used with or without a flush box Cat144 in the wall cavity When using a flush box it should be located directly behind the Wall Mounting Base connector b...

Page 7: ...o turn the heater off Automatic Step down Heat Warm Air 1200W When the room reaches a pre set temperature the heater will automatically step down and reduce the heat output to save power If the room c...

Page 8: ...nd outlet grills Use a damp cloth to clean the exterior of the heater Do not use abrasive cleaning products on this appliance Ensure the heater is dry before turning the power supply back on to the he...

Page 9: ...nder the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the...

Page 10: ...New Zealand PO Box 100707 North Shore Mail Centre Auckland 0745 www goldair co nz Australia PO Box 574 South Morang Victoria 3752 www goldair com au...

Reviews: