Grand and Twin Grand
2848, 2860, and 2873 (32 oz. Pop-O-Golds)
Pop-O-Gold & Medallion (-100 Series)
2948, 2960, and 2973 (52 oz. Medallions)
Page 22
gmpopcorn.com
Issue
Possible Cause
Solution
Yellow Dump Light is ON
or Blinking - Buzzer is
Sounding
(outside of
normal operation)
Dump Light on steady, but
Kettle not heating enough
to pop corn.
A.
Temperature Control
Board has detected an
error condition
A.
A loose kettle lead-in connection can cause a
thermocouple lead issue. (
Units with a
removable kettle
, make sure kettle lead is
plugged in completely and the locking ring is
fully screwed onto kettle receptacle.)
Contact qualified service personnel for
inspection/repair (reference the Electronic
Temperature Control section of this manual
for light indicators or error condition.)
Poor Crisper/Blower
Performance
(Blower is
working, but air not
circulating properly.)
A.
Filters (if equipped)
A.
Clean or replace blower filters as needed
(reference Cleaning and Care section).
B.
Popcorn chaff build up
B.
Have Qualified Service Personnel clean any
popcorn chaff build up from the blower
compartment (reference Cleaning and Care
section).