Grand and Twin Grand
2848, 2860, and 2873 (32 oz. Pop-O-Golds)
Pop-O-Gold & Medallion (-100 Series)
2948, 2960, and 2973 (52 oz. Medallions)
Page 10
gmpopcorn.com
A certified electrician must furnish sufficient power for proper machine operation and install any
supplied receptacle (reference unit Data Plate for model specific Volts AC, Hertz, and Wattage
requirements). We recommend this equipment be on a dedicated and protected circuit. Failure
to wire properly will void the warranty and may result in damage to the machine. It is Gold Medal
Products Co.’s recommendation
that this machine be plugged directly into a wall outlet. The use of
extension cords is not recommended due to safety concerns, and may cause sacrificed and/or
reduced performance. Make sure cord is located to prevent a trip hazard or unit upset.
Receptacle Wiring Diagram for NEMA L14-30 (120V Units)
A certified electrician must follow the IMPORTANT instructions shown for installation of the
L14-30 Receptacle (Gold Medal Item No. 82208) provided with the unit.
If the receptacle is wired incorrectly, the heat elements/kettle and other electrical components could
be at 208 or 240 V potential instead of the needed 120 V, resulting in excessive temperatures in
the heat elements (i.e.: kettle) and possible fire, and/or damage to electrical components.
Receptacle Wiring Diagram for NEMA 14-50 (120V Units)
A certified electrician must follow the IMPORTANT instructions below for installation of the
NEMA 14-50 Receptacle (Gold Medal Item No. 82920) provided with the unit.
If the receptacle is wired incorrectly, the heat elements/kettle and other electrical components
could be at 208 or 240 V potential instead of the needed 120 V, resulting in excessive temperatures
in the heat elements (i.e.: kettle) and possible fire, and/or damage to electrical components.
NEMA 14-50 Receptacle
- Front and Back View
Connect to Green
(Ground) Wire
Connect to Red
(Hot) Wire
Connect to Black
(Hot) Wire
Connect to White
(Neutral) Wire
NEMA L14-30 (30 AMP Receptacle) -
Front and Back View
Green Terminal
Connect to Green
(Ground) Wire
Brass Terminal
Connect to Red
(Hot) Wire
G
Y
Brass Terminal
Connect to Black
(Hot) Wire
Silver Terminal
Connect to White
(Neutral) Wire
X