Golander
BT103S Manual
1
1
Description
The BT103S variable-speed peristaltic pump not only has basic
functions such as start/stop, speed control, prime and reversible
direction, but also upgraded to LCD display, adds time dispense
mode and anti-drip function, and can be easily controlled by the
RS485 communication of the MODBUS protocol.
BT103S flow range 0.00011-480 mL/min, speed 0.1-10 0 rpm.
2
Functions and Features
Advantage of peristaltic pump: Peristaltic pump can handle
extremely viscous fluids, abrasive slurries and corrosive fluids.
There is no seals in contact with the medium pumped and no valves
to clog. The inner surfaces are smooth and easy to clean; fluid
contacts only the tubing or tube material. Suction lift and priming
can be up to 8m water column at sea level. It can handle the most
shear sensitive of fluids like latex or firefighting foam with low
shearing. It is capable of running dry and pumping fluids with high
quantities of entrained air, such as black liquor soap. The high
volumetric efficiency allows operation in metering or dosing
applications where high accuracy is required. Tubing and tube
materials are available for food and pharmaceutical use.
•
LCD displays speed and working mode
•
Keypad for operating
•
Time dispense mode, set the run time, the interval time, the
number of runs
•
High-precision speed control
•
Optional external analog signal controls speed, logic level
signal controls start-stop, directions. Control signals are
optically isolated.
•
RS485 communication, supports MODBUS communication
protocols and facilitates connectivity to a variety of control
devices