Malfunctions caused by flooding!
The product is not designed for installation in areas prone to flooding or risk
areas.
Following flooding, the product must be replaced!
INAPPROPRIATE USE
All uses exceeding the concept of intended use:
Indicator:
•
outdoor use without protection type IP54
•
changes to the product or parts of the product
•
installation in a potentially explosive area
Probe:
•
e.g. operation with different operating media
•
operation with inflammable operating media of categories 1, 2 or 3 with a flash point
<
55°C
1)
1)
It is also necessary to comply with the divergent provisions/regulations of the EU
member states concerning areas at risk of explosion and the flash point of the operating
medium!
•
installation in pressurised tanks and containers
USER QUALIFICATION
This product may be installed only by qualified experts. These are personnel who are familiar
with setting up, installing, starting up, operating and maintaining this product.
"Equipment and systems requiring supervision may be operated only by persons aged at
least 18, who are physically capable and who have the necessary specialist knowledge or
who have been instructed by a competent person. Instruction at regular intervals, but at least
once per year, is recommended."
Activity
Qualification
storing, transporting, unpacking, OPERATION
trained personnel
ASSEMBLY, MAINTENANCE
START-UP, SHUT-DOWN , REPLACEMENT,
RESTART, RESTORATION, DISPOSAL,
qualified personnel, customer service
ELECTRICAL INSTALLATION
qualified electrician
ASSEMBLY
Before assembly, check that the product is complete and has not suffered any damage during
transport.
ASSEMBLY, STARTUP and MAINTENANCE are to be carried out by a company
specialised in terms of water law.
The specialised company and the operator must observe, comply with and understand all of
the following instructions in this assembly and operating manual. For the system to function
as intended, it must be installed professionally in compliance with the technical rules
applicable to the planning, construction and operation of the entire system.
These regulations also include the accident prevention regulations of the employers’ liability
insurance associations, the VDE regulations, and the installation and operating instructions.
The housing of the display unit is suitable for wall mounting and is connected to
the 230 V mains supply. Under normal circumstances, the display unit must be operated with
the housing cover closed.
It is installed and started up by a qualified technician while the unit is open.