Artikel-Nr. 27 105 50 a
15 / 48
Do not open!
Do not remove cover (or back of the Leak Check LPG PRO).
No user-serviceable parts inside.
Maintenance work (calibration of the test device) may only be carried out by
qualified personnel
Unplug the device if it is not in use and when it is being cleaned!
Can result in short circuit or electric shock.
Do not open the housing when the device is connected to the power supply!
Do not use cleaning agents to clean the device!
Use only a dry cloth to clean the device!
Observe the safety precautions and the assembly and operating instructions of
connected devices.
GENERAL PRODUCT INFORMATION
The electronic test device Leak Check LPG PRO is equipped with all the parts needed to
check for leaks in LPG systems in recreational vehicles.
When the electronic test device is connected to the supply line using the enclosed connection
parts, it checks for leaks automatically.
After a positive check, the log with the test result is printed from the connected printer on long-
life paper, which can be attached to the test certificate of the LPG system. If there is a leak in
the supply line, the pump can generate the test pressure continuously, which considerably
simplifies searching for the leak by an expert* see USER QUALIFICATION.
Pressure sensor
•
For the pressure measurement to function properly, the test hose for the test device must
be open/unpressurised when the electronic test device is switched on (see error messages
E1 - E5
). If possible, the measurements should be carried out at an ambient temperature of
between 15°C and 25°C.
•
The pressure sensor will be damaged if external pressure is applied or if liquid is fed
into the electronic device.
INTENDED USE
The electronic test device is used to check for leaks in LPG systems in leisure vehicles and
small boats (e.g. , for tests by experts according to Worksheets G 607, ÖVGW G 107 and EN
1949 or in small boats according to Worksheets G 608 and EN ISO 10239).
If it is not used as intended, all warranty and product liability claims shall be void.
The electronic test device is not approved for use in explosive areas/zones.
Place of operation
•
operate indoors and outdoors, if protected against the weather
May not be used in explosion-prone areas.
Can cause an explosion or serious injuries.
Installation outside the defined ex zone.
Area of Application
•
Caravans
•
Motor caravans
•
Sport boats
To be used only for installed LPG systems and LPG-operated devices in
caravans and motor homes and in small boats with a hull length up to 24m.