Regulator heating type ES2000
10 / 12
Part No. 05 220 52 a
TROUBLESHOOTING
If the heater unit does not warm up, follow the next steps.
Step
Power available
No power available
1. Check secondary
12 V AV voltage on
transformer
Heater unit defective
Detach the cable on the power supply
unit and replace the complete heater
unit
Follow step 2
2. Check voltage on
transformer
Check fuse
Remove fuse holder and, if necessary,
replace microfuse
(see Figure 2,
Item 4)
Replace fuse holder in the opening
Transformer defective
Replace complete power supply unit
Check installation
Check socket
MAINTENANCE
With proper assembly and operation, the product is maintenance free.
SHUT-DOWN
Press the switch to "OFF" to switch the product off.
REPAIRS
If the measures explained above under TROUBLESHOOTING do not result in regular
START-UP, and if there is no dimensioning problem, the product must be sent to the
manufacturer for a check. Our warranty does not apply in cases of unauthorised interference.
DISPOSAL
To protect the environment, our products may not be disposed of along
with household waste.
The product must be disposed of via a local collection station or a recycling
station. If you do not have any possibilities for proper disposal, contact us