PRO-HDBaseT2P
12
1. Short blackout periods are expected when new monitors are connected to
the splitter. The splitter will do Automatic EDID learning which analyzes the
newly connected monitor to see if the EDID for the HDMI input is necessary
to update!
2. Firmware update is proceed through Micro-USB
9. Notice
System firmware update
(1)Save the firmware file (.bin) & software in the same folder.
(2)Please try to adjust dip switch [pin1, pin 2]=[
-
]
(3)Connect the Micro-USB cable between PC and device
(4)Open firmware update software and then device will start to update firm
ware automatically
(5)After update process is done, software will show “Success” message and
then be closed automatically.
(6)Power cycle the device
Output 1 firmware update
(1)Please adjust dip switch [pin1, pin 2]=[
-
]
(2)Connect the Micro-USB cable between PC and device
(3)Open the firmware update software
(4)Set the correct COM port and baud rate (57600 is recommended)
(5)Click the FILE button to load firmware file (.hex or .bin file)