![Godox KNOWLED M600 Bi Instruction Manual Download Page 22](http://html1.mh-extra.com/html/godox/knowled-m600-bi/knowled-m600-bi_instruction-manual_2238113022.webp)
1.Download the new firmware to the U disk from the official website (http://www.go
-
dox.com.cn/Downloads.html).
2.Turn off the LED light. Insert the U disk with new firmware into the USB upgrade port.
3. Turn on the LED Light, and it will automatically enter the upgrading interface..
4.It will return to main interface after completion.
Notes:
1. New firmware must be downloaded from the official website, and keep only one BIN
file in the root directory of the USB disk.
2. The USB port can only support firmware upgrade function.
41
42
CCT mode: Maximum Brightness (%) in Fan Off Mode when supplied by V-mount battery
CCT mode: Maximum Brightness (%) in Low-Speed Cooling Mode when supplied by
V-mount battery
V-mount battery
14.8V(single)
14.8V(double)
26V(single)
14.8V+26V
26V(double)
linear
20
%
25
%
25
%
25
%
25
%
S-curve
30
%
35
%
35
%
35
%
35
%
exponential
50
%
55
%
55
%
55
%
55
%
logarithmic
4
%
4
%
4
%
4
%
4
%
V-mount battery
14.8V(single)
14.8V(double)
26V(single)
14.8V+26V
26V(double)
linear
20%
40%
30%
50%
50%
S-curve
30%
43%
38%
48%
48%
exponential
50%
72%
63%
78%
78%
logarithmic
4%
8%
5%
10%
10%
If the temperature of the light body is too
high, the Over-Temperature Protection
icon flashes on the main interface, the
light body can be used normally.
If the temperature of the light body
exceeds the limit of Over-Temperature
Protection, the Over-Temperature Protec-
tion icon flashes on the main interface and
the screen works properly after the light
goes out in 3 seconds. When the tempera-
ture decreases to 50 ° C, the Over-Tem-
perature Protection icon disappears, then
the light body can resume working.
Fan Mode
Auto Cooling
Off
Low-Speed Cooling
High-Speed Cooling
linear
100%
25%
50%
100%
S-curve
100%
35%
48%
100%
exponential
100%
55%
78%
100%
logarithmic
100%
4%
10%
100%
V-mount battery
14.8V(single)
14.8V(double)
26V(single)
14.8V+26V
26V(double)
Auto Cooling
20%
40%
30%
50%
60%
Off
20%
25%
25%
25%
25%
Low-Speed Cooling
20%
40%
30%
50%
50%
High-Speed Cooling
20%
40%
30%
50%
60%
CCT mode: Maximum Brightness (%) in different Fan Mode when supplied by AC power
Auto Cooling
Off
Low-Speed Cooling
High-Speed Cooling
100%
25%
50%
100%
FX mode: Maximum Brightness (%) in different Fan Mode when supplied by AC power
FX mode: Maximum Brightness (%) in different Fan Mode when supplied by V-mount
battery
Note: The dimming curve is not adjustable in FX mode, it is linear in default.
The above data is based on 26V 270Wh 10.5Ah battery and 14.8V 150Wh 10.2Ah battery.
Software Upgrade
Over-Temperature Protection