4.0 Choosing a Location
The GP-PWM-10 is designed to be mounted against a wall, out of the
way but easily visible.
The GP-PWM-10 should be:
•
Mounted as close to the battery as possible
•
Mounted on a vertical surface to optimize cooling of the unit
•
Indoors, protected from the weather
In an RV, the most common controller location is above the refrigerator.
The wire from the solar array most commonly enters the RV through the
fridge vent on the roof or by using the Go Power! Cable Entry Plate (sold
separately) that allows installers to run wires through any part of the roof.
PV connections should connect directly to the controller. Positive and
negative battery connections must connect directly from the controller to
the batteries. Use of a positive or negative distribution bus is allowed
between the controller and battery as long as it is properly sized,
electrically safe and an adequate wire size is maintained.
5.0 Installation Instructions
1. Complete the installation of the solar modules.
If this
GP-PWM-10 was purchased as part of a Go Power! Solar
Power Kit, follow the Installation Guide provided. Otherwise,
follow manufacturer’s instructions for solar module mounting
and wiring.
2. Select wire type and gauge.
If this GP-PWM-10 was
purchased as part of a Go Power! Solar Power Kit, appropriate
wire type, gauge and length is provided. Please continue to
Section 6
, “Operating Instructions.” If the GP-PWM-10 was
purchased separately, follow the instructions included here.
Wire type is recommended to be a stranded copper UV resistant wire.
Wire fatigue and the likelihood of a loose connection are greatly reduced
in stranded wire compared to solid wire. Wire gauge should be able to
sustain rated current and minimize voltage drop.