GP-PWM-10
_________________________________________________________________________________
11
© 2017 Go Power!®
To confirm the battery profile,
press and hold the
A Button
for 3 seconds.
Non-volatile memory:
Any
settings made on the GP-
PWM-10 will be saved even
when the power has been
disconnected from the
controller.
Refer to the Battery Charge
Profile Chart below for details
on each profile.
7.3 Battery Charging Profile Chart
Battery Type
SEALED
/GEL
AGM
FLOODED
LFP
Float Charge
@ 25°C:
13.7V (+/- 0.1V)
N/A
Bulk/Absorption Charge
@ 25°C:
Set to 30 minutes every morning.
Applied for 2 hours if the battery
voltage drops below 12.3 volts.
14.1V
(+/- 0.1V)
14.4V
(+/-
0.1V)
14.4V
(+/- 0.1V)
N/A
Equalization Charge
@ 25°C
:
Applied for 2 hours every 28 days
and if the battery voltage drops
below 12.1 volts.
N/A
N/A
14.9V
(+/-0.1V)
N/A
Absorption Charge voltage for
LiFePO
4
:
Set to 30 minutes every morning
N/A
14.4VDC
Float Charge voltage for LiFePO
4
:
N/A
14.0VDC
If a charging cycle is unable to complete in a single day, it will continue the following day. The
terms SEALED/GEL, AGM, FLOODED and LFP are generic battery designations. Choose the
charging profile that works best with your battery manufacturer’s recommendations.