8. Operating Instructions
8.1 Power Up
When the GP-PWM-30 is connected
to the battery, the controller will go into
Power Up mode.
Icons Displayed:
All segments of
the numerical display blink
Depending on the battery voltage when the GP-PWM-30 Power Up occurs, the controller
may do a Boost Charge or quickly go into Float Charge. The Charging Profile selected
will commence the following day after a Power Up (refer to the Charging Profile Chart
on page 15 for more details).
8.2
Setting the Battery Type and Charging Profile
To select the battery charging profile, press and hold the
B Button.
This will cause
the current battery type to blink.
Setting Battery 1
To set the battery type for Battery
1, hold the
B Button
for 3 seconds.
When the display shows a blinking
number 1, release the
B Button
.
Next, select the charging profile
of Battery 1. Press and hold the
B Button
(the current selected
battery type will blink). Then press the
B Button
to toggle through the profile
options: Sealed/Gel, AGM or Flooded.
To confirm the battery profile, press
and hold the
A Button
for 3 seconds.
page 11