Recommended distances between portable and mobile RF communication equipments and the 

Syncrus G8 Dental Chair

The 

Syncrus G8 Dental Chair

 is made to be used in an electromagnetic environment in which

RF disturbances are controlled. The client or the user of the 

Syncrus G8 Dental Chair

 may

help preventing electromagnetic interference by keeping a minimal distance between mobile 

and portable RF communication equipment (transmitters) and the 

Syncrus G8 Dental Chair

 

as recommended below, in accordance with the maximal voltage output of the communication 

equipment.

Transmitter Maximum

Output (W)

Separation distance according to transmitter frequency (M)

150 kHz to 80 MHz

d= 1,2√p

80 kHz to 800 MHz

d= 1,2√p

800 kHz to 2,5 GHz

d= 2,3√p

0,01

0,12

0,12

0,23

0,1

0,38

0,38

0,73

1

1,2

1,2

2,3

10

3,8

3,8

7,3

100

12

12

23

For transmitters with a maximum nominal output power not listed above, the recommended 

d

 

separation distance in meters 

(M)

 can be determined using an equation applicable to the frequency

of the transmitter, where 

P

 is the transmitter maximum nominal output in watts 

(W)

 according 

to the transmitter manufacturer.

NOTE 1  At 80MHz and 800MHz, is applied the separation distance for the higher frequency range.

NOTE 2  These guidelines may not apply to all situations. The absorption and reflection from 

structures, objects and people affect the electromagnetic propagation.

TECHNICAL SPECIFICATIONS

Summary of Contents for Syncrus G8

Page 1: ......

Page 2: ... Est 582 002 897 114 Rod Abrão Assed Km 53 450m Cx Postal 782 CEP 14097 500 Ribeirão Preto S P Brasil Phone 55 16 2102 5000 Technical Duties Ricardo J Ravaneli CREA SP 5060714523 Registration ANVISA 10069210062 For greater safety Read and understand all the instructions contained in these instructions for use before installing or operating this equipment Note These instructions for use must be rea...

Page 3: ... and operation 29 Sensibility to predictable environmental conditions in regular use conditions 29 Precaution and warnings during the installation of the equipment 30 Precautions and warnings during the use of equipment 30 Precautions and warnings after the use of equipment 30 Precautions and warnings during the cleaning and disinfection of equipment 31 Precautions in case of alteration in the fun...

Page 4: ...ntal use use only It must be operated and utilized by specialized professional certified professional according to the legislation of the country and following the instructions of the manual The operation of the equipment required for the professional the utilization of correct instruments and it should to be in perfect conditions of the use and to protect the professional the patients and others ...

Page 5: ... with nanotechnology superficial treatment High gloss flat epoxybased paint polymerized in oven at 250 C resistant to corrosion and cleaning materials Equipped with an exclusive Robotic Massaging System with two massage point chest and seat with 3 programs Wave Continuous and Pulse with manual speed and intensity control The Massager provides great comfort to the patient allowing them to relax dur...

Page 6: ...ing and accessories 01 Headrest 02 Thorax chest backrest 03 Upper bearing cover 04 Base 05 Inferior Cover 06 Wired system pedal 07 General Key On Off switch 08 Cover motor finishing 09 Footrest 10 Retractable seat 11 Fixed arm 12 Retractable arm WARNING For the chair with integrated connection box is recommended to fix the base of the chair to the floor as oriented under the item Installation of t...

Page 7: ...7 04 05 06 01 09 02 03 07 08 MODULES ACCESSORIES OPTIONS AND MATERIALS OF CON SUMPTION ...

Page 8: ... 08 Retractable arm 09 Cervical support Attention The drawing illustrates all the optional items page 07 therefore your equipment will consist only of the chosen items selected during your purchase option The use of any part accessory or material not specified or provided in these use instructions is of entire responsibility of the user Items optional MODULES ACCESSORIES OPTIONS AND MATERIALS OF C...

Page 9: ... Part Type B Mode of Operation Continuous with intermittent load T on 1min T off 4min Protection against harmful water penetration or particulate material IPX0 All the chair excepting foot control IPX1 Foot control Input power 530VA Protection fuses F1 and F2 T8A 250V Rising capacity Distributed load of 200 kg Patient mass accessories and equipment Net Weight 127 Kg Gross Weight 160 Kg ...

Page 10: ...ting further complications Current surge protection The equipment is endowed with high current safety device that uses 2 fuses and internal overpower protection for the equipment that is attached to the chair Electronic system Chair features an low voltage electronic system which allows complete interface with Gnatus reflectors equipment and electronic water units not only providing security to bo...

Page 11: ... 1 This Syncrus G8 Dental Chair uses RF energy only for internal functions However its emissions are too low and it s unlikely to cause any interference in the equipments next to it RF emissions ABNT NBR IEC CISPR 11 Class B Emissions of harmonics IEC 61000 3 2 Class A This Syncrus G8 Dental Chair is proper to be used in all establishments including domestic settings and those directly connect to ...

Page 12: ... 2kV lines s to ground It is advisable that the quality of the power supply should be that of hospital or typical commercial environment Reduction i n t e r r u p t i o n and variance of voltage in power supply input lines IEC 61000 4 11 5 Ut 95 drop in Ut for 0 5 cycle 40 Ut 60 drop in Ut for 5 cycles 70 Ut 30 drop in Ut for 25 cycles 5 Ut 95 drop in Ut for 5s 5 Ut 95 drop in Ut for 0 5 cycles 40...

Page 13: ...transmitter as determined by means of electric inspection on sitea is less than the level of compliance in each frequancy rangeb There may be interference near the equipment marked with the following symbol NOTE 1 At 80MHz and 800MHz the highest frequency range applies NOTE 2 These directives may not be applicable in every situation The electromagnetic transmission is affected by the absorption an...

Page 14: ...paration distance according to transmitter frequency M 150 kHz to 80 MHz d 1 2 p 80 kHz to 800 MHz d 1 2 p 800 kHz to 2 5 GHz d 2 3 p 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters with a maximum nominal output power not listed above the recommended d separation distance in meters M can be determined using an equation applicable to the frequency o...

Page 15: ...15 Dimensions mm TECHNICAL SPECIFICATIONS ...

Page 16: ...ported away from direct sun light exposure Packing to be transported and or stored with care should not suffer drop and neither receive impact Temperature limit for the packing to be stored or transported Applied part type B Grounding at several points of the equipment indicates the condition of being grounded Attention Check the working instructions Note It indicates useful information for operat...

Page 17: ...r patient Turned on position Turned off position Lift seat Lower seat Lift backrest Lower backrest It determines the initial position Activation of the dental light It determines the work position 1 and 2 It determines the work position 3 and 4 Emergency stop It determines to spitting position last position Product symbols TECHNICAL SPECIFICATIONS ...

Page 18: ...he factory positioned at 220V so ensure that your network is compatible before turning it on If it is 127V request the presence of an authorized GNATUS technician INFRA STRUCTURE SPECIFICATION The perfect functioning and the durability of the Gnatus dental set are directly linked to the preinstallation which must be carried out by duly trained professionals according to the instructions contained ...

Page 19: ...r is fastened to the floor by means of the holes already furnished in its base This means that the added weight does not jeopardize the stability of the set How to fix the dental chair base to the floor Mark the floor stick with 12mm drill insert two S12 screw plastic plugs in the holes place the chair aligned to the holes and fix it using 3 8 x 90mm hex head steel screws and washers Base pierced ...

Page 20: ...e the articulated headrest release the lever c pulling it up find the desired position and move the lever down to lock the mechanism Click To move the headrest pivot articulation press the Hold Key d Find the desired position and release the key to lock Initiating After positioning the chair in the chosen place Turn on the general key on off switch located on the engine cover trim side a Thru the ...

Page 21: ... this function interrupting all movements and preventing further complications Easy fix Backrest s upholstery is removable thanks to the Easy fix system To remove it just pull To place it again find the correct position and push fixing the upholstery to the backrest e Headrest bracket To adjust height just move it vertically Items optional OPERATION OF EQUIPMENT ...

Page 22: ...eumatic operation 07 Chip Blower System double function operation key Spray or Air 08 Emergency Stop 09 Emergency Led 10 Lift backrest 11 Lower backrest 12 Activation of the dental light 13 Lift seat 14 Lower seat 15 Carrying Handle mobile Foot control 01 NOTE For the Delivery Units without Bien Air System the key of the Foot control 04 will have the function of inverting the rotation of the elect...

Page 23: ...he key 12 the activation of the dental light Working Positions The Syncrus G8 Dental Chair has four working positions In order to program them just place the chair in the position and the dental light at the desired intensity and press and hold for 3 seconds the working position 1 and 2 button 01 or working position 3 and 4 button 02 at the pedal the dental chair will sound a beep and then two bee...

Page 24: ...sition 03 the light source will turn off if it was on water will then flow in the basin for the duration of the programmed time or if this has not been programmed for 4 minutes the chair back will raise completely to the Spitting Position when pressing it again the back support will return to the previous position and the light source will turn on if it was on When pressing the button Return to ze...

Page 25: ... When lowering of rising backrest the seat automatically moves improving the patient s comfort At the backrest lowest position the pa tient can lie down in the Trendelemburg position legs and pelvis 01 are loca ted in a higher position than thorax and head 02 Bump preventing device The Dental chair features a leg bump preventing device 03 When the chair was descending any obstruction below the cha...

Page 26: ...ndicates the current option Note When activated the wave option it will automatically activate the 02 zones Z1 and Z2 05 Zone 1 Zone 2 Selection of the area to be massa ged Back or legs or even selecting both zones at the same time Led indicates the current option In case the 02 zones are selected both Leds will be lighted up 06 On Off and functioning time The Led indicates the current option 1º S...

Page 27: ... be edited and keys 02 which allow the setting of values from 0 to 99 and such percentages are shown in the right side of the display in green color 01 When the Menu key 03 is activated it will alternate in the left side in red color from numbers 1 and 2 When number 1 speed of the massager and when number 2 intensity Massager Control Functions Wave Mode In this mode the massagers increase and redu...

Page 28: ...in and observe the maximum stack quantity specified in the packaging Environmental condition for transportation or storage Room temperature range for transportation or storage 29ºC to 60ºC Relative humidity range for transportation or storage 20 to 90 Atmospheric pressure range 500hPa to 1060 hPa 375 mmHg to 795 mmHg Environmental condition for storage among the operations Room temperature range f...

Page 29: ...equipment can only be unpacked and installed by an Gnatus authorized technician under the penalty of losing the warranty as only them possess the information the proper tools and the required training for carrying out this task Gnatus does not take this responsibility for damage or accidents caused due to a bad installation performed by a technician non authorized by Gnatus Only after the equipmen...

Page 30: ...ic parts to contact with chemical substances use in the routines of dental treatment such as acids mercury acrylic liquids amalgams etc When moving the chair never get it for the part of the support of the legs lift it for the structure in the area of the seat Gnatus shall not be responsible for Use of the equipment differing from that for which it is intended Damages caused to the equipment the p...

Page 31: ...NTENANCE AND PRESERVATION Attention In order to prevent risks and damages to equipment make sure that the liquid does not enter into the equipment To cleaning the equipment using the damp cloth with a mild soap The application of other solvent based cleaning products or sodium hypochloride isn t recommended because they may damage the equipment Cleaning Important In order to execute cleaning or an...

Page 32: ... presents any abnormality check if the problem is related to some of the listed items under the item Unpredictable situation cause and solution If it s not possible to solve the problem shutdown the equipment and demand the presence of a Gnatus technician from the nearest resale or ask through the Attendance Service Gnatus 55 16 3512 1212 Corrective Maintenance Gnatus states that the supplying of ...

Page 33: ...Blown fuse s Activate the power button of the Massager Check the connections Power the chair off and request the presence of a Technician FINAL CONSIDERATIONS Among the care you have to take with your equipment the most important is regarding of the spare parts replacement To ensure the lifetime of your device only replace original spare parts from Gnatus They have the assurance of the standards a...

Page 34: ...34 ...

Page 35: ...35 ...

Page 36: ......

Reviews: