D6030 

- SIL 3 Switch/Proximity Detector Repeater Relay Output 

G.M. International ISM0213-2 

MODEL D5030S

5 +

6 -

1

2

Out NO Contact (SIL 3)

=

=

=

=

7

8

Power and

Fault Bus

+

-

F

Supply 24 Vdc

3

4

Out NC Contact (SIL 3)

+

-

In

Proximity

voltage free

Contact

voltage free

Contact

R1

R2

Function Diagram 

 

Relay contact shown in de-energized position. 

Terminals 1-2 open, terminals 3-4 close. 

Internal Dip switches programmable 

Relay contacts shown in de-energized position. 

Terminals 1-2 and 3-4 open. 

Relay contacts shown in de-energized position. 

Terminals 1-2 and 3-4 open. 

Resistors R1 - R2 used with 

voltage free contact required 

for line fault detection. 

MODEL D5030D

5 +

6 -

1

2

Out 1 (SIL 3)

10

+

-

In 1

Proximity

=

=

=

=

voltage free 

Contact

7

8

Power and

Fault Bus

+

-

F

Supply 24 Vdc

3

4

Out 2 (SIL 3)

+

-

In 2

Proximity

=

=

=

=

voltage free 

Contact

9

voltage free 

Contact

voltage free 

Contact

R1

R2

R1

R2

MODEL D5030D Duplicator or Fault Out

5 +

6 -

1

2

Out 1 (SIL 3)

=

=

=

=

7

8

Power and

Fault Bus

+

-

F

Supply 24 Vdc

3

4

Out 2  Duplicator or Fault

9

10

+

-

In

Proximity

voltage free 

Contact

voltage free 

Contact

R1

R2

Resistors R1 - R2 used with 

voltage free contact required 

for line fault detection. 

Terminals 9-10 must be 

shorted to set module as 

Duplicator or Fault Out 

Resistors R1 - R2 used with 

voltage free contact required 

for line fault detection. 

 (SIL 3)

MODEL D6030D 

MODEL D6030D Duplicator or Fault Out 

MODEL D6030S 

Summary of Contents for D6030D

Page 1: ...6030 SIL 3 Switch Proximity Detector Repeater Relay Output G M International ISM0213 2 SIL 3 Switch Proximity Detector Repeater Relay Output DIN Rail Models D6030S D6030D D6030S D6030D INSTRUCTION MANUAL ...

Page 2: ...85 W for 2 channels D6030D 0 45 W for 1 channel D6030S with 24 V supply voltage short circuit input and relay energized typical Isolation Test Voltage In Out 2 5 KV In Supply 2 5 KV In In 500 V Out Supply 2 5 KV Out Out 2 5 KV Input switching current levels ON 2 1 mA 1 9 to 6 2 mA range OFF 1 2 mA 0 4 to 1 3 mA range switch current 1 65 mA 0 2 mA hysteresis Fault current levels open fault 0 2 mA s...

Page 3: ... used as fault indicator only 2nd ch Systematic capability SIL 3 2 fully independent channels High Density 2 channels per unit NO NC switch proximity Detector Input NE ND relay actuation mode Field open and short circuit detection Three port isolation Input Output Supply EMC Compatibility to EN61000 6 2 EN61000 6 4 EN61326 1 EN61326 3 1 for safety system In field programmability by DIP Switch TÜV ...

Page 4: ...oltage free contact required for line fault detection MODEL D5030D 5 6 1 2 Out 1 SIL 3 10 In 1 Proximity voltage free Contact 7 8 Power and Fault Bus F Supply 24 Vdc 3 4 Out 2 SIL 3 In 2 Proximity voltage free Contact 9 voltage free Contact voltage free Contact R1 R2 R1 R2 MODEL D5030D Duplicator or Fault Out 5 6 1 2 Out 1 SIL 3 7 8 Power and Fault Bus F Supply 24 Vdc 3 4 Out 2 Duplicator or Fault...

Page 5: ...ovable screw terminal blocks which can be plugged in out into a powered unit without suffering or causing any damage The wiring cables have to be proportionate in base to the current and the length of the cable On the section Function Diagram and enclosure side a block diagram identifies all connections Identify the number of channels of the specific card e g D6030S is a single channel model and D...

Page 6: ...mity sensor Enabled proximity sensor or switch with end of line resistors de energizes relay in fault condition 9 NO 10 OR NC 9 10 9 NO 10 OR NC 9 10 NE 3 4 3 ND 4 Output 3 ND 4 Output NE 3 4 3 3 ON OFF 4 4 ON OFF Position in fault condition 3 4 1 2 3 4 5 6 7 8 ON Dip switch factory settings All Switches are OFF Input Input Output Input Output Input 2 CH1 Setting Line fault detection IN OUT Operat...

Page 7: ...Mode ON OFF OFF ON 2 ON 2 OFF Disabled switch proximity sensor Enabled proximity sensor or switch with end of line resistors de energizes relay in fault condition No Fault No Fault 1 OFF 5 OFF 5 ON Output 2 Operation Input Input Output 1 Input Output 1 Input 7 NO 8 OR NC 7 8 7 NO 8 OR NC 7 8 NE 1 2 1 ND 2 Output 1 1 ND 2 Output 1 NE 1 2 NE 3 4 3 ND 4 Set SW4 equal to SW2 Set SW4 opposite to SW2 6 ...

Page 8: ...g Line fault detection IN OUT Operation NO NE or NC ND NO ND or NC NE 2 ON 2 OFF Disabled switch proximity sensor Enabled proximity sensor or switch with end of line resistors de energizes relay in fault condition 1 OFF 5 OFF 1 ON 5 ON Input Input Input Input 7 NO 8 OR NC 7 8 7 NO 8 OR NC 7 8 Output 1 3 2 4 NE Output 1 3 2 4 NE Output 1 3 2 4 ND Output 2 4 ND 1 3 Position in fault condition 1 3 2 ...

Page 9: ... resistors detects field open circuit and short circuit de energizes relay in fault condition ON ON ON 1 IN OUT Operation SW2 NO NE or NC ND ON NO ND or NC NE for SIL application OFF Channel 1 2 SW4 ON OFF D6030D used as double channel Configuration Summary Table WARNING dip switch 6 7 8 must be set to OFF position Line fault detection SW1 SW5 Disabled switch proximity sensor OFF OFF Enabled for S...

Reviews: