background image

 

D5212

 - SIL 2 Quadruple Repeater Power Supply 

G.M. International ISM0361-3 

10 

Param. 

Description 

Notes 

Type 

(11)

 

Output 

Configuration 

R/W  

194 

Output3 Under Range (Low 16 bits) 

(1) 

195 

Output3 Under Range (High 16 bits) 

(1) 

196 

Output3 Over Range (Low 16 bits) 

(1) 

197 

Output3 Over Range (High 16 bits) 

(1) 

198 

Output3 Fault Current (Low 16 bits) 

(1) 

199 

Output3 Fault Current (High 16 bits) 

(1) 

200 

Output3 Fault Mask 

(3) 

202 

Output3 InputA Selector 

(4) 

203 

Output3 InputB Selector 

(4) 

204 

Output3 Operation 

(5) 

205 

Output4 Downscale (Low 16 bits) 

(1) 

206 

Output4 Downscale (High 16 bits) 

(1) 

207 

Output4 Upscale (Low 16 bits) 

(1) 

208 

Output4 Upscale (High 16 bits) 

(1) 

209 

Output4 Under Range (Low 16 bits) 

(1) 

210 

Output4 Under Range (High 16 bits) 

(1) 

211 

Output4 Over Range (Low 16 bits) 

(1) 

212 

Output4 Over Range (High 16 bits) 

(1) 

213 

Output4 Fault Current (Low 16 bits) 

(1) 

214 

Output4 Fault Current (High 16 bits) 

(1) 

215 

Output4 Fault Mask 

(3) 

217 

Output4 InputA Selector 

(4) 

218 

Output4 InputB Selector 

(4) 

219 

Output4 Operation 

(5) 

220 

Fault Bus Configuration 

(4) 

Fault Config. 

R/W 

240 

Alarm Configuration 

(6) 

Alarm Control 

R/W 

242 

Alarm Startup Lock 

(7) 

243 

Alarm Fault Configuration 

(8) 

244 

Alarm Fault Mask 

(3) 

245 

Contact Position in Case of Alarm 

(9) 

246 

Delay to Alarm Issue

 (10) 

247 

Delay to Alarm Removal 

(10) 

248 

Alarm Low Threshold (Low 16 bits) 

(1) 

249 

Alarm Low Threshold (High 16 bits) 

(1) 

250 

Alarm Low Threshold Hysteresis (Low 16 bits) 

(1) 

251 

Alarm Low Threshold Hysteresis (High 16 bits) 

(1)

 

252 

Alarm High Threshold (Low 16 bits) 

(1) 

253 

Alarm High Threshold (High 16 bits) 

(1) 

254 

Alarm High Threshold Hysteresis (Low 16 bits) 

(1) 

255 

Alarm High Threshold Hysteresis (High 16 bits) 

(1)

 

256 

Alarm InputA Selector 

(4) 

257 

Alarm InputB Selector 

(4) 

258 

Alarm Operation Selector 

(5) 

464 

EEPROM Write 

Command 

548 

Output 1 virtual value (Low 16 bits) 

(1) 

Output Data 

549 

Output 1 virtual value (High 16 bits) 

(1) 

Output Data 

553 

Output 2 virtual value (Low 16 bits) 

(1) 

Output Data 

554 

Output 2 virtual value (High 16 bits) 

(1) 

Output Data 

558 

Output 3 virtual value (Low 16 bits) 

(1) 

Output Data 

559 

Output 3 virtual value (High 16 bits) 

(1) 

Output Data 

563 

Output 4 virtual value (Low 16 bits) 

(1) 

Output Data 

564 

Output 4 virtual value (High 16 bits) 

(1) 

Output Data 

567 

Alarm status 

(7) 

Alarm Data 

600 

Ch. 1 chars 0, 1 

Tags 

R/W 

601 

Ch. 1 chars 2, 3 

Tags 

R/W 

602 

Ch. 1 chars 4, 5 

Tags 

R/W 

603 

Ch. 1 chars 6, 7 

Tags 

R/W 

604 

Ch. 1 chars 8, 9 

Tags 

R/W 

605 

Ch. 1 chars 10, 11 

Tags 

R/W 

606 

Ch. 1 chars 12, 13 

Tags 

R/W 

607 

Ch. 1 chars 14, 15 

Tags 

R/W 

608 

Ch. 2 chars 0, 1 

Tags 

R/W 

609 

Ch. 2 chars 2, 3 

Tags 

R/W 

610 

Ch. 2 chars 4, 5 

Tags 

R/W 

611 

Ch. 2 chars 6, 7 

Tags 

R/W 

612 

Ch. 2 chars 8, 9 

Tags 

R/W 

613 

Ch. 2 chars 10, 11 

Tags 

R/W 

614 

Ch. 2 chars 12, 13 

Tags 

R/W 

615 

Ch. 2 chars 14, 15 

Tags 

R/W 

616 

Ch. 3 chars 0, 1 

Tags 

R/W 

617 

Ch. 3 chars 2, 3 

Tags 

R/W 

618 

Ch. 3 chars 4, 5 

Tags 

R/W 

619 

Ch. 3 chars 6, 7 

Tags 

R/W 

620 

Ch. 3 chars 8, 9 

Tags 

R/W 

621 

Ch. 3 chars 10, 11 

Tags 

R/W 

622 

Ch. 3 chars 12, 13 

Tags 

R/W 

623 

Ch. 3 chars 14, 15 

Tags 

R/W 

624 

Ch. 4 chars 0, 1 

Tags 

R/W 

625 

Ch. 4 chars 2, 3 

Tags 

R/W 

626 

Ch. 4 chars 4, 5 

Tags 

R/W 

627 

Ch. 4 chars 6, 7 

Tags 

R/W 

628 

Ch. 4 chars 8, 9 

Tags 

R/W 

629 

Ch. 4 chars 10, 11 

Tags 

R/W 

630 

Ch. 4 chars 12, 13 

Tags 

R/W 

631 

Ch. 4 chars 14, 15 

Tags 

R/W 

 Supported ModBus Parameters:  

ModBus parameters details: 

Notes: 

(1)  Expressed in 100 nA 
(2)  0 = No fault, 

1 = Input out of range 

(3)  0 = Ignore input fault, 

1 = Report input out of range 

(4)  0 = Input1, 

1 = Input2, 
2 = Input3, 
3 = Input4 

(5)  0 = None, 

1 = Sum, 
2 = Subtraction, 
3 = Maximum, 
4 = Minimum 

(6)  0 = None, 

1 = Low, 
2 = High, 
3 = Window, 
4 = Fault repeater 

(7)  0 = Inactive, 

1 = Active 

(8)  0 = Ignore, 

1 = Lock status, 
2 = Alarm active, 
3 = Alarm inactive 

(9)  0 = Open, 

1 = Closed 

(10)  Expressed in tenths of seconds 
(11) Parameter type: 

R = read only, 
W = write only, 
R/W = read and write 

1  Save Input/Output Configuration  
2  Save Modbus configuration 
8 Save 

Tags 

Address 464: EEPROM Write

 

High Byte 

Low Byte 

Bit position 

15  14  13  12  11  10  9  8  7  6  5  4 3 2 1 0 

Summary of Contents for D5212Q

Page 1: ...D5212 SIL 2 Quadruple Repeater Power Supply G M International ISM0361 3 SIL 2 Quadruple Repeater Power Supply DIN Rail and Termination Board Model D5212Q D5212Q INSTRUCTION MANUAL...

Page 2: ...e mode current limited at about 25 mA Response time 100 ms max 10 to 90 step change Output ripple 20 mVrms on 250 Modbus Output for parameter configuration and burnout fault indication Modbus RTU prot...

Page 3: ...instruments associated with the barrier Terminal block connections HAZARDOUS AREA SAFE AREA Output Ch 1 1 Output Ch 1 2 Output Ch 2 3 Output Ch 2 4 Output Ch 3 5 Output Ch 3 6 Power Supply 24 Vdc 9 P...

Page 4: ...ea Hazardous Locations and group encountered and that its maximum allowable voltage current power Ui Vmax Ii Imax Pi Pi are not exceeded by the safety parameters Uo Voc Io Isc Po Po of the D5212Q Asso...

Page 5: ...I I I In 2 In 4 2 Wire Tx 2 Wire Tx External Powered Tx 2 Wire Tx 2 Wire Tx Common positive connection for passive transmitter input SIL 2 SIL 2 SIL 2 SIL 2 Common negative connection for active tran...

Page 6: ...all connections Identify the function and location of each connection terminal using the wiring diagram on the corresponding section as an example Connect 24 Vdc power supply positive at terminal 9 an...

Page 7: ...range 0 to 24 mA Over range analog output value in over range condition range 0 to 24 mA Fault output value analog output value in case of fault condition range 0 to 24 mA Fault in case of analog outp...

Page 8: ...nts the second operand used for the output operation Input 2 represents the second operand used for the output operation Input 3 represents the second operand used for the output operation Input 4 rep...

Page 9: ...ult High 16 bits 1 129 Input4 Downscale Low 16 bits 1 130 Input4 Downscale High 16 bits 1 131 Input4 Upscale Low 16 bits 1 132 Input4 Upscale High 16 bits 1 133 Input4 Fault Switch 3 134 Input4 Low Ra...

Page 10: ...High 16 bits 1 Output Data R 553 Output 2 virtual value Low 16 bits 1 Output Data R 554 Output 2 virtual value High 16 bits 1 Output Data R 558 Output 3 virtual value Low 16 bits 1 Output Data R 559...

Reviews: