background image

 

12 

D1061 

- RS422 / RS485 Fieldbus Isolating Repeater 

G.M. International ISM0068-12 

2

1

1

2

8

7

6

5

Side B Panel View 

OFF 



Baud rate Configuration 

Baud Rate 

1.500.000 

 

 

OFF 

OFF 

 

 

OFF 

OFF 

1.000.000 

OFF 

OFF 

ON 

OFF 

750.000 

OFF 

ON 

OFF 

OFF 

500.000 

OFF 

ON 

ON 

OFF 

375.000 

ON 

OFF 

OFF 

OFF 

187.500 

ON 

OFF 

ON 

OFF 

93.750 

ON 

ON 

OFF 

OFF 

115.200 

ON 

ON 

ON 

ON 

57.600 

OFF 

OFF 

OFF 

ON 

38.400 

OFF 

OFF 

ON 

ON 

19.200 

OFF 

ON 

OFF 

ON 

14.400 

OFF 

ON 

ON 

ON 

9.600 

ON 

OFF 

OFF 

ON 

4.800 

ON 

OFF 

ON 

ON 

2.400 

ON 

ON 

OFF 

ON 

1.200 

ON 

ON 

ON 

Hazardous 

Area 

Termination 

250 

 between 

A- and B+ 

Disabled 

 

 

SW1 

1

2

3

4

ON

Switch positions

Termination Resistor

Configuration

(Hazardous Area)

SW1

ON 

ON ON 

OFF OFF 



Termination Resistor Configuration 

Factory settings 

Factory settings 

Summary of Contents for D1061S

Page 1: ...D1061 RS422 RS485 Fieldbus Isolating Repeater ISM0068 12 D1061S INSTRUCTION MANUAL RS422 RS485 Fieldbus Isolating Repeater Din Rail Model D1061S...

Page 2: ...ssion speed 1 2 2 4 4 8 9 6 14 4 19 2 38 4 57 6 93 75 115 2 187 5 375 500 750 Kbit s or 1 0 1 5 Mbit s DIP switch configurable RS422 RS485 Transmission cable length 1200 m up to 93 75 Kbit s 1000 m up...

Page 3: ...X IECEx FM FM C INMETRO EAC EX UKR TR n 898 Certifications Type Approval Certificate KR for marine applications High Reliability SMD components Simplified installation using standard DIN Rail and plug...

Page 4: ...13 14 15 16 Li Li device L cable Li Ri device and L cable R cable 15 16 13 14 15 16 13 14 15 16 When used with separate powered intrinsically safe devices check that maximum allowable voltage current...

Page 5: ...IC SAFE AREA ZONE 2 GROUP IIC T4 NON HAZARDOUS LOCATIONS CLASS I DIVISION 2 GROUPS A B C D T Code T4 CLASS I ZONE 2 GROUP IIC T4 MODEL D1061S 13 14 15 3 4 5 6 7 Supply 24 Vdc 8 6 5 8 3 9 4 A B A 16 B...

Page 6: ...S I DIVISION 2 GROUPS A B C D T Code T4 CLASS I ZONE 2 GROUP IIC T4 MODEL D1061S 13 14 15 3 4 5 6 7 Supply 24 Vdc 8 6 5 8 3 9 4 B A 16 9 10 31 A B 5 V SUB D 9 poles female connector RT RT 2 1 RT 31 2...

Page 7: ...T RS485 Field Devices From 200 to 1200 m depending on data rate MODEL D1061S 13 14 15 3 4 5 6 7 Supply 24 Vdc 8 6 5 8 3 9 4 B A 16 9 10 31 A B 5 V RT RT 2 1 RT RS485 Field Devices From 200 to 1200 m d...

Page 8: ...epaired by the end user and must be returned to the manufacturer or his authorized representative Any unauthorized modification must be avoided Warning Operation D1061 fieldbus isolating repeater prov...

Page 9: ...ct transmitting section at terminal 15 and 16 corresponding to A and B Connect field serial line type RS485 or receiving section of RS422 in Safe Area at terminal 5 and 6 corresponding to A and B In a...

Page 10: ...istors can also be configured Dip switch configuration Side A Panel View SW2 SW3 Safe Area Serial Line Connection Type RS232 RS422 5 V on pin 6 SUB D connector Unconnected pin 6 SUB D connector RS485...

Page 11: ...parity 1 stop bit 9 7 data bit no parity 2 stop bit 7 data bit odd parity 1 stop bit 7 data bit even parity 1 stop bit 8 data bit no parity 1 stop bit 10 10 10 10 OFF ON OFF OFF ON ON ON 7 data bit o...

Page 12: ...FF OFF OFF 187 500 ON OFF ON OFF 93 750 ON ON OFF OFF 115 200 ON ON ON ON 57 600 OFF OFF OFF ON 38 400 OFF OFF ON ON 19 200 OFF ON OFF ON 14 400 OFF ON ON ON 9 600 ON OFF OFF ON 4 800 ON OFF ON ON 2 4...

Reviews: