background image

 

D1061 

- RS422 / RS485 Fieldbus Isolating Repeater 

G.M. International ISM0068-12 

 

Ordering information 

Model:   D1061S 

Power Bus enclosure 

/B 

 

Front Panel and Features 



Input/Output from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2. 



RS422 / RS485 Hazardous Area I.S. Signal. 



RS232 / RS422 / RS485 Safe Area Signal. 



Transmission speed up to 1.5 Mbit/s. 



For Modbus, Fieldbus, Profibus and all other RS485 protocols. 



Three port isolation, Input/Output/Supply. 



EMC Compatibility to EN61000-6-2, EN61000-6-4. 



In-field programmability by DIP Switch. 



ATEX, IECEx, FM & FM-C, INMETRO, EAC-EX, UKR TR n. 898 Certifications. 



Type Approval Certificate KR for marine applications. 



High Reliability, SMD components. 



Simplified installation using standard DIN Rail and plug-in terminal blocks. 



250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. 

D1061 

1  2  3  4 

9  10  11  12 

16 

15 

14 

13 

5  6  7  8 

           PWR ON 

Tx  Rx 

To shield 

Terminal block connections 

HAZARDOUS AREA 

SAFE AREA 

To shield 

Not used 

Not used 

A - for IN/OUT RS485 orTxD RS422 

B + for IN/OUT RS485 orTxD RS422 

A - for RxD RS422 

B - for RxD RS422 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

Not used 

1

 

Not used 

2

 

+ Power Supply 24 Vdc 

3

 

- Power Supply 24 Vdc 

4

 

A - for IN/OUT RS485 orTxD RS422 

5

 

B + for IN/OUT RS485 orTxD RS422 

6

 

A - for RxD RS422 

7

 

B - for RxD RS422 

8

 

Summary of Contents for D1061S

Page 1: ...D1061 RS422 RS485 Fieldbus Isolating Repeater ISM0068 12 D1061S INSTRUCTION MANUAL RS422 RS485 Fieldbus Isolating Repeater Din Rail Model D1061S...

Page 2: ...ssion speed 1 2 2 4 4 8 9 6 14 4 19 2 38 4 57 6 93 75 115 2 187 5 375 500 750 Kbit s or 1 0 1 5 Mbit s DIP switch configurable RS422 RS485 Transmission cable length 1200 m up to 93 75 Kbit s 1000 m up...

Page 3: ...X IECEx FM FM C INMETRO EAC EX UKR TR n 898 Certifications Type Approval Certificate KR for marine applications High Reliability SMD components Simplified installation using standard DIN Rail and plug...

Page 4: ...13 14 15 16 Li Li device L cable Li Ri device and L cable R cable 15 16 13 14 15 16 13 14 15 16 When used with separate powered intrinsically safe devices check that maximum allowable voltage current...

Page 5: ...IC SAFE AREA ZONE 2 GROUP IIC T4 NON HAZARDOUS LOCATIONS CLASS I DIVISION 2 GROUPS A B C D T Code T4 CLASS I ZONE 2 GROUP IIC T4 MODEL D1061S 13 14 15 3 4 5 6 7 Supply 24 Vdc 8 6 5 8 3 9 4 A B A 16 B...

Page 6: ...S I DIVISION 2 GROUPS A B C D T Code T4 CLASS I ZONE 2 GROUP IIC T4 MODEL D1061S 13 14 15 3 4 5 6 7 Supply 24 Vdc 8 6 5 8 3 9 4 B A 16 9 10 31 A B 5 V SUB D 9 poles female connector RT RT 2 1 RT 31 2...

Page 7: ...T RS485 Field Devices From 200 to 1200 m depending on data rate MODEL D1061S 13 14 15 3 4 5 6 7 Supply 24 Vdc 8 6 5 8 3 9 4 B A 16 9 10 31 A B 5 V RT RT 2 1 RT RS485 Field Devices From 200 to 1200 m d...

Page 8: ...epaired by the end user and must be returned to the manufacturer or his authorized representative Any unauthorized modification must be avoided Warning Operation D1061 fieldbus isolating repeater prov...

Page 9: ...ct transmitting section at terminal 15 and 16 corresponding to A and B Connect field serial line type RS485 or receiving section of RS422 in Safe Area at terminal 5 and 6 corresponding to A and B In a...

Page 10: ...istors can also be configured Dip switch configuration Side A Panel View SW2 SW3 Safe Area Serial Line Connection Type RS232 RS422 5 V on pin 6 SUB D connector Unconnected pin 6 SUB D connector RS485...

Page 11: ...parity 1 stop bit 9 7 data bit no parity 2 stop bit 7 data bit odd parity 1 stop bit 7 data bit even parity 1 stop bit 8 data bit no parity 1 stop bit 10 10 10 10 OFF ON OFF OFF ON ON ON 7 data bit o...

Page 12: ...FF OFF OFF 187 500 ON OFF ON OFF 93 750 ON ON OFF OFF 115 200 ON ON ON ON 57 600 OFF OFF OFF ON 38 400 OFF OFF ON ON 19 200 OFF ON OFF ON 14 400 OFF ON ON ON 9 600 ON OFF OFF ON 4 800 ON OFF ON ON 2 4...

Reviews: