background image

Crathco® Beverage Dispensers

Page 7

ROUTINE MAINTENANCE:

For all Models

Cleaning Your Dispenser

To optimize performance or when using dairy products, clean unit daily.
Regular cleaning of bowl components will result in maximum pumping efficiency, proper seating and sealing, and
prevention of leaks at the valve O-Ring and bowl gasket by removing dried-on beverage solids and pulp from mov-
ing sealed parts.
1. Wash all bowl components regularly. Follow all local health codes.

* Refer to Disassembly, Cleaning, and Assembly instructions on pages 4-6.

Sanitizing Your Dispenser

* Refer to Disassembly and Assembly instructions on pages 4-6.
1. In the bowl, mix one gallon of Oxford Chemical’s Disinfectant/Sanitizer Formula C or its equivalent. 
2. Turn on spray motor(s) and allow sanitizer to spray around inside of bowl for a period of time as recommended by 

the sanitizer manufacturer. Formula C is satisfactory for this purpose when mixed in a solution of 1 liquid ounce of 
cleaner to 4 gallons of water. Run spray motor(s) for 60 seconds. In areas with extreme hard water, consult the 
local health authority.

3. Drain sanitizer 

completely 

and 

thoroughly

during each step of the cleaning process (wash, rinse, and sanitize). 

Refer to tips on draining in Disassembly Guide on page 6.

HELPFUL HINTS

1. 

Noisy Impeller:

Do not run impeller dry. The impeller will make a chattering sound in an empty bowl. Remove the 

impeller and run a small amount of water in the bowl.

2. 

Valve and O-Ring: 

On the first installation, if there is an after-drip, place your hand on the valve and with a slight 

downward pressure turn it slightly. This will help seat the o-ring so that it is properly aligned  
with the valve seat. If an o-ring becomes cut or worn it should be replaced. If you are pumping 
a product which has excessive pulp, a separate valve weight may be purchased to add extra 
weight so the o-ring will press down against the pulp and guarantee a positive shut-off.

3. 

Valve Cap Use: 

The Valve Cap (Part # 2039) insures that a tight valve seal will occur with 

products containing heavy pulp. The Valve Cap can be installed by placing it on top of the 
Valve after the Valve has been assembled into the bowl. See Figure D.

4. 

High Water Marks on Bowl: 

When you agitate, you may get “high water marks” as the 

beverage level drops. Keep the bowl as full as possible. 

5. 

Spray or Agitate?: 

Most beverages can be sprayed. It is best not to spray iced tea, 

iced coffee, natural juices, or beverages that foam (whipped drinks). A special agitator plate 
(included) is used in place of a pump cover and spray tube to promote circulation.

6. 

Proper Cooling: 

Always keep spray switch on when refrigeration switch is on. A unit must

spray or agitate to cool. Failure to do this will cause impeller to lock-up. The dispenser is 
designed to run 24 hours a day. Keep both spray and agitate on when beverage is in the bowls.

7. 

Condensation: 

Condensation on the bowls and lids is natural, cool, and refreshing. The amount of condensation 

is affected by humidity. Condensation will run down the front panel into the drip tray. Remember to occasionally 
empty the drip trays. 

8. 

Single Bowl Operation: 

If you find it necessary to run your dispenser with only one bowl containing beverage, 

put one half (1/2) cup of water in the unused cooling plate depression(s) for best one-bowl operation and 
efficiency.

VALVE CAP

VALVE

Figure D

Summary of Contents for Crathco Classic Bubbler D Series

Page 1: ...ive Maintenance 8 Troubleshooting Guide 9 Parts Identification 10 MCX Mag Drive Impeller 12 GMCW 4003 Collins Lane Louisville KY 40245 USA 502 425 4776 800 695 4500 USA Canada only Fax 502 425 4664 Em...

Page 2: ...Plug into properly grounded NEMA5 15R receptacle with a dedicated circuit breaker 4 Assemble bowl parts and drain trays See Assembly instructions pgs 4 5 See Figure C 5 77 F 86 F 25 C 30 C is suitabl...

Page 3: ...sh lockdown washer down and into locking keyway slide into locked position place BOWl GasKeT On BOWl Turn bowl upside down and place bowl gasket over the neck of the bowl Moisten gasket with water or...

Page 4: ...e product Keep food or product preparation area utensils equipment and surroundings clean POUR CONCENTRATE INTO DISPENSER then add remaining water per product label PREPARE PRODUCT CONCENTRATE by mixi...

Page 5: ...parts in sanitizing solution for 1 2 minutes Remove parts from sanitizing solution and drain DO NOT RINSE Place parts on a clean surface to air dry Wipe the machine condensate tray and cooling plate...

Page 6: ...pressure turn it slightly This will help seat the o ring so that it is properly aligned with the valve seat If an o ring becomes cut or worn it should be replaced If you are pumping a product which h...

Page 7: ...leeve all units except D112 3220 Large Blue Impeller D WD model 1161 Small Red Impeller E model 1008 Universal Impeller all models 3587 Valve O ring 1012 Bowl Gasket for D WD models 5 gallon or 3 gall...

Page 8: ...ion Compressor Does Not Run Call for service No Spray or Agitation Spray Motor Runs Chattering Impeller Impeller does not spin check for worn bearing sleeve and or impeller see page 5 Impeller chatter...

Page 9: ...over for Red p n 1008 or Black p n 3587 Impeller use with spray tube All D15 D25 D35 HD and WD models 1740 Agitator for use with Red p n 1008 or Black p n 3587 Impeller All D15 D25 D35 HD and WD model...

Page 10: ...d 2266 Dispense Valve Handle pictured w std bowl assembly photo 2484 Non Contact Handle pictured w std bowl assembly photo 2660 Mini Quad Drip Tray Plastic 2682 Mini Quad Drip Tray Grid 2802 Standard...

Page 11: ...uilt simple Built stronger Built to last Specifications and Use Part 3587 Recommended for use in all models MCX Mag Drive Impeller by Crathco Purely the Best Bowl size Recommended Pump Cover when spra...

Reviews: