background image

Power tool use and care

•  

Do not force the power tool.

 Use the correct power 

tool for your application. The correct power tool will 

do the job better and safer at the rate for which it 

was designed.

•  

Do not use the power tool if the switch does 

not turn it on and off.

 Any power tool that cannot 

be controlled with the switch is dangerous and must 

be repaired.

•  

Disconnect the plug from the power source 

before making any adjustments, changing 

accessories, or storing power tools.

 Such 

preventive safety measures reduce the risk of starting 

the power tool accidentally.

•  

Store idle power tools out of the reach of children 

and do not allow persons unfamiliar with the 

power tool or these instructions to operate the 

power tool.

 Power tools are dangerous in the hands 

of untrained users.

•  

Maintain power tools.

 Check for misalignment 

or binding of moving parts, breakage of parts and 

any other condition that may affect the power tool’s 

operation. If damaged, have the power tool repaired 

before use. Many accidents are caused by poorly 

maintained power tools.

•  

Keep cutting tools sharp and clean.

 Properly 

maintained cutting tools with sharp cutting edges are 

less likely to bind and are easier to control.

•  

Use the power tool, accessories and tool bits etc., 

in accordance with these instructions and in the 

manner intended for the particular type of power 

tool, taking into account the working conditions 

and the work to be performed.

 Use of the power 

tool for operations different from intended could result 

in a hazardous situation.

Service

•   

Have your power tool serviced by a qualified  

     repair personnel using only identical replacement  

     parts. 

•     

When operating a power tool outdoors, use an 

outdoor extension cord suitable for outdoor use. 

Use of a cord suitable for outdoor use reduces 

the risk of electric shock.

 This will ensure that the 

safety of the power tool is maintained.

Additional safety instructions for 

engravers

• Always wear eye, ear and breathing protection
• Do not apply too much pressure when engraving

WARNING.

 The use of an accessory or attachment, 

other than those recommended in this Instruction 

Manual, may present a risk of personal injury.
To use this tool properly, you must observe the safety 

regulations, the assembly instructions and the operating 

instructions to be found in this Manual. All persons who 

use and service the machine have to be acquainted with 

this Manual and must be informed about its potential 

hazards. Children and infirmed people must not use this 

tool. Children should be supervised at all times if they 

are in the area in which the tool is being used. It is also 

imperative that you observe the accident prevention 

regulations in force in your area. The same applies for 

general rules of occupational health and safety.
The manufacturer shall not be liable for any changes 

made to the tool nor for any damage resulting from such 

changes.
Even when the tool is used as prescribed it is not 

possible to eliminate all residual risk factors. The 

following hazards may arise in connection with the tool’s 

construction and design:
•    Damage to the lungs if an effective dust mask is 

     not worn.
•    Damage to hearing if effective earmuffs are not worn.
•    Damage to eyes if effective goggles are not worn
•    Risk of injury unless hands are kept well clear of  

     cutting devices

Unpacking

Due to modern mass production techniques, it is unlikely 

that your GMC Power Tool is faulty or that a part is 

missing. If you find anything wrong, do not operate the 

tool until the parts have been replaced or the fault has 

been rectified. Failure to do so could result in serious 

personal injury.

Installing an engraver tip 

WARNING.

 Disconnect the engraver from the power 

supply before making any adjustments or maintenance 

procedures. 
1.  Loosen the tip release screw (4) by turning it anti- 

     clockwise with a flat head screwdriver.
2.  To fit the new engraving tip (2), insert the tip through  

     the centre of the hole of the engraver, ensuring the  

     tip fully enters the housing. A new tip should protrude 

     from the end of the housing by approximately 8.5mm.
3.  Tighten the tip release screw (4) fully by rotating in a  

     clockwise direction. 

Operation 

WARNING.

 Always wear safety glasses when using 

this tool.
The GMC engraver can be used to permanently mark 

metal, glass, plastic, wood, ceramics and much more. 
1.   Before using the engraver you must ensure there is 

an engraving tip installed.

2.  Connect the engraver plug to the power supply and  

     while holding the engraver firmly, push up on the  

     on/off switch (1) with your thumb. 

NOTE.

 To turn the tool on, press the small On/Off 

Switch (1) upwards to the (I) position. To turn the tool off, 

push the on/off Switch (1) down to the (O) position. 
3.  Hold the engraver at an angle, like you would hold a  

     pen. Do not press down hard while engraving, use  

     light pressure while guiding the point over the work to  

     be completed.

Adjusting the depth of engraving 

1.  The stroke adjustment dial (3) located on the side of  

     the engraver controls the stroke length and therefore  

     the depth of engraving. 
2.  For a fine mark turn the stroke adjustment dial (3)  

     anti-clockwise to position ‘1’.
3.  For a deeper, thicker mark turn the stroke adjustment  

     dial (3) clockwise to position ‘5’

NOTE.

 It is recommended that you practice on scrap 

material before you start. 

Maintenance

WARNING.

 Always ensure that the tool is switched 

off and the plug is removed from the power point before 

making any adjustments or maintenance procedures.
1.  Use a soft brush to remove any accumulated dust.  

     Wear safety glasses to protect your eyes whilst  

     cleaning.
2.  If the body of the tool needs cleaning, wipe it with a  

     soft damp cloth. A mild detergent can be used but  

     never alcohol, petrol or other harsh cleaning agents.
3.  Never use caustic agents to clean plastic parts.

CAUTION.

 Water must never come into contact with 

the tool.

General inspection

Regularly check that all the fixing screws are tight. They 

may vibrate loose over time.

Power cord maintenance

If the supply cord needs replacing, the task must be 

carried out by the manufacturer, the manufacturer’s 

agent, or an authorised service centre in order to avoid 

a safety hazard.
Please refer to your warranty card, which is separate to 

these instructions.

45–55 South Centre Road Melbourne Airport

Victoria, Australia 3045

Tel: (03) 8346 1100  Fax: (03) 8346 1200

                    

Full 2-Year Warranty

This product is warranted for a 2-year period for 

home domestic use from the date of the original 

purchase. If found to be defective in materials 

or workmanship, the tool or the offending faulty 

component will be replaced free of charge with 

another of the same item. A small freight charge 

may apply.
The warranty replacement unit is only made 

available by returning the tool to the place of 

purchase with a confirmed register receipt. 

Proof of purchase is essential. We reserve the 

right to reject any claim where the purchase 

cannot be verified. This warranty does not 

include damage or defects to the tool caused by 

or resulting from abuse, accidents, alterations or 

commercial or business use.
Consistent with our product development 

programme, improvements may have been made 

which render the contents of the tool’s packaging 

or user instructions slightly different to the 

product received.
Phone (03) 8346 1100  Facsimile (03) 8346 1200    

Email [email protected]

Website www.gmcompany.com  

Copyright Global Machinery Company Australia 

Proprietary Limited, 2001
Dear customer, if you require any help with your 

product, whether it is a Warranty Claim, spare 

part or user information, please phone our 

Help Line 

1300 880 001 (Australia) 

or 0800 445 721 (New Zealand), for an 

immediate response. 
Product of China manufactured to exacting 

GMC quality standards.  
ABN: 68 093 174 808

The GMC 777 Helpline 

operates from 7am to 

7pm, 7 days a week (EST). 

This allows you to contact GMC directly with 

any queries and technical questions you have 

regarding our products.

Save this Manual for future reference.

 

Summary of Contents for DEC001SI

Page 1: ...fumes Keep children and bystanders away while operating a power tool Distractions can cause you to lose control Electrical safety If cordset is damaged have it replaced by an authorised service centre Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electr...

Page 2: ...until it has entirely cooled down Preparing to solder WARNING Always use safety glasses and ensure the work area is well ventilated to help avoid breathing in dangerous fumes The GMC Soldering Iron is typically used to melt and apply solder on various surfaces including circuit boards 1 Before beginning to solder secure the work piece so that it does not move and affect your accuracy 2 Prepare a d...

Page 3: ...outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded Do not expose power tools to rain or wet ...

Page 4: ...he battery pack when the temperature is below 4 C or above 40 C This is important Failure to observe this safety rule could cause serious damage to the battery pack Do not incinerate the battery pack even if it is seriously damaged or can no longer hold a charge The battery pack can explode in a fire Never attempt to open the battery pack for any reason If the plastic housing of the battery pack b...

Page 5: ...lugs and matching outlets will reduce risk of electric shock Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock Do not abuse the cord Never use the...

Page 6: ...t go any further 3 Tighten the collet nut 6 with the wrench by turning the nut clockwise 4 Thread the flexible shaft collet cover onto the tool housing by turning it clockwise and finger tighten only WARNING Never tighten the collet nut with the use of pliers or a wrench as the thread will strip Changing the collet and accessories Note To change the collet or install a cutter or accessory into the...

Page 7: ...te cool down of the tool Specifications Input power 13W Power supply 230 240V 50 Hz Engraving bit Tungsten Carbide Tipped steel Cord length 1 4 metres Tool Weight 0 4 kg Safety instructions WARNING Read and understand all instructions Failure to follow all instructions listed below may result in electric shock fire and or serious injury The term power tool in all of the warnings below refers to yo...

Page 8: ... the new engraving tip 2 insert the tip through the centre of the hole of the engraver ensuring the tip fully enters the housing A new tip should protrude from the end of the housing by approximately 8 5mm 3 Tighten the tip release screw 4 fully by rotating in a clockwise direction Operation WARNING Always wear safety glasses when using this tool The GMC engraver can be used to permanently mark me...

Reviews: