Test Before Permanently 

Mounting

After confirming that your LTR-P-WP pre-configured 

order is accurate, lay everything out and connect 

per these instructions.  

Fig. 1.

Test tape installation by powering up before 

permanently mounting.  If tape does 

perform satisfactorily, check our FAQ / Trou-

bleshooting tips on page 7.

Mounting With 3M Adhesive 

Tape

Your LTR-P-WP configured layout came with enough 

3M double stick tape to adhere your complete 

configured                    application to the surface.  

Peel back paper covering to expose adhesive and then 

carefully press ribbon into place.  

Fig. 2.

Using Mounting Channels

See ‘Using Mounting Channels’ instructions on 

Page 4.  Drill mounting holes using counter-sunk 

screws (by others).  

Fig. 3.

.  Lay in tape with using 

3M double stick tape to insure that tape is securely 

in position within channel.  Attach frosted lens.  

Connectors do not fit in all channels.

Using Silicone Mounting Clips

Using the supplied tube of silicone gel, squeeze gel 

into end cap and push onto end of run, capping off 

the final length of tape. 

Fig. 4.

LEDTask™ Flexible LED Tape

LTR-P WP Series

Wet Location LED Tape

Terminating Run with End Cap

Using the supplied tube of silicone gel, squeeze gel 

into end cap and push onto end of run, capping off the 

final length of tape. 

Fig. 5.

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Silicone sealant

(supplied with wet location 

tape)

End cap

Fig. 5

 

 

Summary of Contents for LEDTask LTR-E Series

Page 1: ...lation into GM Lighting LED mounting channels for proper heat control 7 To avoid voltage drop ensure that wire gauge used is sufficient to keep under 3 voltage drop See Voltage Drop Chart on Page 7 8 Do not exceed maximum run listed for each tape type and for power supply per circuit on dual circuit models 9 Cut at designated cut points only Fig 1 Cutting anywhere else will result in damage to the...

Page 2: ... may hamper installation or get in the way of wiring Please make sure that the wire gauge that you select has voltage drop amperage rating and type in wall dry or wet loca tion etc factored in Layout and Pre Configure Components Before You Begin Installation Locate area where LineDRIVE power supply is to be mounted Make sure that this space is free of obstructions and can be easily reached for mou...

Page 3: ...same procedure for connecting Sure Tite connector The other end of connector is wired into your LineDRIVE power supply Please consult power supply instructions for a step by step for this easy procedure Make sure that you you are connected to the same polarity Warning Make sure that tape is pressed firmly into connector insuring that tape contacts are firmly seated into connector Improper or loose...

Page 4: ...ut a channel for your installation take note that not all channels accept connectors within them Best to make your connections outside of the channel Cut channels with the lens fitting down to avoid shattering Cut channel using a metal blade in a circular saw or with a hacksaw Make sure you observe all proper safety precautions and wear protective goggles If using a hacksaw insure that channel is ...

Page 5: ...ris that may hamper installation or get in the way of wiring Please make sure that the wire gauge that you select has voltage drop amperage rating and type in wall dry or wet location etc is factored in Un Boxing and Organizing Pre Configured Products Your LTR WP Series Wet Location Tape Application has been pre configured cut and packaged for you Open box and remove contents carefully Lay tape ou...

Page 6: ...lace Fig 2 Using Mounting Channels See Using Mounting Channels instructions on Page 4 Drill mounting holes using counter sunk screws by others Fig 3 Lay in tape with using 3M double stick tape to insure that tape is securely in position within channel Attach frosted lens Connectors do not fit in all channels Using Silicone Mounting Clips Using the supplied tube of silicone gel squeeze gel into end...

Page 7: ...the choice of magentic or electronic is correct for your tape Brightness shifting Power supply is over loaded and is overheating An over loaded power supply will trip the internal auto reset repeat edly turning the system on and off If all else fails We re here for you Call our technical service reps at 866 671 0811 or write to tech gmlighting net 12V Wire Voltage Drop Wire Gauge 10W 83A 20W 1 7A ...

Page 8: ... SUPPLY 120V EXAMPLE Single Run see voltage drop chart POWER SUPPLY 120V EXAMPLE Multi Run 120VAC V V V V HIGH OUTPUT LED TAPE LONGER RUN WIRING EXAMPLE 12VOR 24V 100W POWER SUPPLY 16 4 16 4 16 4 16 4 32 8 STANDARD OUTPUT LED TAPE LONGER RUN WIRING EXAMPLE 32 8 16 4 16 4 120VAC 12VOR 24V 100W POWER SUPPLY ...

Page 9: ...WITH TAPE CONTROLLER 120 VAC INPUT OUTPUT GND LUX CONTROLLER V V GND L N USING SWITCHLD DIMMER DRIVER SYSTEM 120 VAC GND L N INPUT OUTPUT LUX CONTROLLER V V GND SWITCHLD DIMMER STANDARD DIMMER USING STANDARD DIMMER WITH LINEDRIVE ELECTRONIC DIMMABLE POWER SUPPLY 120 VAC INPUT OUTPUT GND LINEDRIVE DIMMABLE POWER SUPPLY V V GND L N ...

Page 10: ... Ridgeland Ave Tinley Park IL 60477 Toll Free 866 671 0811 FAX 708 478 2640 www gmlighting net e mail sales gmlighting net tech gmlighting net 2021 GM Lighting Specifications subject to change without notice ...