background image

 

LEDTASKtapeINST

PAGE 3 OF 10

Cutting Tape

LED tape is unique in the fact that it is the only 

lighting ‘fixture’ that you can cut to length with 

only a pair of scissors.  We made it easy for you to 

do that!  Find the cut mark closest to your desired 

length and cut cleanly, across the marks. 

Fig. 1  

Peel back adhesive 1/2” to expose back of tape.  

You are now ready for attaching a connector 

Fig. 2.  

If you’re at the end of your run, you’re done. 

Attaching Connector

Using Sure-Tite Connector (ST or EST Series)

Loosen screws at end of connector.  Slide tape in 

firmly, pushing it all the way until it stops.  Make 

sure that tape is seated firmly, creating a tight bond 

with the connector.  Snug-tight screws, 

do not 

overtighten.

  

Fig. 3.

Attaching Power to Tape 

Connector 

Use same procedure for connecting Sure-Tite 

connector.  The other end of connector is wired into 

your LineDRIVE power supply.  Please consult 

power supply instructions for a step by step for 

this easy procedure.  

Make sure that you you are 

connected to the same polarity.

Warning

Make sure that tape is pressed firmly into 

connector, insuring that tape contacts are firmly 

seated into connector.  Improper or loose seating 

can cause tape to short out or not perform properly.

Test tape installation by powering up before 

permanently mounting.  If tape does not 

perform satisfactorily, check our FAQ / Trou-

bleshooting tips on page 7.

LEDTask™ Flexible LED Tape

LTR-E, LTR-P and LTR-S Series

Dry Location LED Tape

Cut on mark

Fig. 1

1/2”

Expose back of

strip before 

connecting

Fig. 2

SureTite Connector

Fig. 3

Flip open

and seat tape

firmly under

terminals   

Fig. 4

Cut marks are spaced at 

different lengths depending on

the type of tape.  All cut marks

are clearly marked on tape.

Summary of Contents for LEDTask LTR-E Series

Page 1: ...lation into GM Lighting LED mounting channels for proper heat control 7 To avoid voltage drop ensure that wire gauge used is sufficient to keep under 3 voltage drop See Voltage Drop Chart on Page 7 8 Do not exceed maximum run listed for each tape type and for power supply per circuit on dual circuit models 9 Cut at designated cut points only Fig 1 Cutting anywhere else will result in damage to the...

Page 2: ... may hamper installation or get in the way of wiring Please make sure that the wire gauge that you select has voltage drop amperage rating and type in wall dry or wet loca tion etc factored in Layout and Pre Configure Components Before You Begin Installation Locate area where LineDRIVE power supply is to be mounted Make sure that this space is free of obstructions and can be easily reached for mou...

Page 3: ...same procedure for connecting Sure Tite connector The other end of connector is wired into your LineDRIVE power supply Please consult power supply instructions for a step by step for this easy procedure Make sure that you you are connected to the same polarity Warning Make sure that tape is pressed firmly into connector insuring that tape contacts are firmly seated into connector Improper or loose...

Page 4: ...ut a channel for your installation take note that not all channels accept connectors within them Best to make your connections outside of the channel Cut channels with the lens fitting down to avoid shattering Cut channel using a metal blade in a circular saw or with a hacksaw Make sure you observe all proper safety precautions and wear protective goggles If using a hacksaw insure that channel is ...

Page 5: ...ris that may hamper installation or get in the way of wiring Please make sure that the wire gauge that you select has voltage drop amperage rating and type in wall dry or wet location etc is factored in Un Boxing and Organizing Pre Configured Products Your LTR WP Series Wet Location Tape Application has been pre configured cut and packaged for you Open box and remove contents carefully Lay tape ou...

Page 6: ...lace Fig 2 Using Mounting Channels See Using Mounting Channels instructions on Page 4 Drill mounting holes using counter sunk screws by others Fig 3 Lay in tape with using 3M double stick tape to insure that tape is securely in position within channel Attach frosted lens Connectors do not fit in all channels Using Silicone Mounting Clips Using the supplied tube of silicone gel squeeze gel into end...

Page 7: ...the choice of magentic or electronic is correct for your tape Brightness shifting Power supply is over loaded and is overheating An over loaded power supply will trip the internal auto reset repeat edly turning the system on and off If all else fails We re here for you Call our technical service reps at 866 671 0811 or write to tech gmlighting net 12V Wire Voltage Drop Wire Gauge 10W 83A 20W 1 7A ...

Page 8: ... SUPPLY 120V EXAMPLE Single Run see voltage drop chart POWER SUPPLY 120V EXAMPLE Multi Run 120VAC V V V V HIGH OUTPUT LED TAPE LONGER RUN WIRING EXAMPLE 12VOR 24V 100W POWER SUPPLY 16 4 16 4 16 4 16 4 32 8 STANDARD OUTPUT LED TAPE LONGER RUN WIRING EXAMPLE 32 8 16 4 16 4 120VAC 12VOR 24V 100W POWER SUPPLY ...

Page 9: ...WITH TAPE CONTROLLER 120 VAC INPUT OUTPUT GND LUX CONTROLLER V V GND L N USING SWITCHLD DIMMER DRIVER SYSTEM 120 VAC GND L N INPUT OUTPUT LUX CONTROLLER V V GND SWITCHLD DIMMER STANDARD DIMMER USING STANDARD DIMMER WITH LINEDRIVE ELECTRONIC DIMMABLE POWER SUPPLY 120 VAC INPUT OUTPUT GND LINEDRIVE DIMMABLE POWER SUPPLY V V GND L N ...

Page 10: ... Ridgeland Ave Tinley Park IL 60477 Toll Free 866 671 0811 FAX 708 478 2640 www gmlighting net e mail sales gmlighting net tech gmlighting net 2021 GM Lighting Specifications subject to change without notice ...