DESCRIPTION
EC 65
12/09
7
3
Force range adjusting
slide
The range in which the crimp die is pressed together
with full force can be set with this slide. If the die meets
with an obstruction outside this range, the crimping die
open immediately to avoid damage to the die or to the
falsely inserted material.
Position 1: min. force range
Position 5: max. force range
4
Crimp die
Positions the crimp contact and presses this together
with the wire.
It consists of the top and bottom die. These can be
changed depending on the application.
5
Protective cover
Prevents injury to fingers and hands in the danger area
of the crimp die.
The EC 65 only works when the protective cover is fully
inserted.
6
Handle
Serves for transporting the EC 65.
7
Connection foot
switch
Device connection for the foot switch.
8
Mains connection
Device connection for the power cable.
9
Mains fuses
Fine fuses (2x) integrated in the mains connection.
10
Power switch
Switches on the power supply (I pressed) or off
(0 pressed). The LED on the
control panel
lights up after switching on.
11
Foot switch
Pressing the foot switch triggers the crimping process.
The foot switch must be kept pressed until the crimp die
is fully closed (mode 1) or the crimp contact is clamped
(mode 2).
If the LED lights up on the
control panel
the
crimping process cannot be triggered.
Summary of Contents for EC 65
Page 2: ...EC 65...
Page 4: ......
Page 6: ......
Page 33: ...EC 65 Operating Manual Electric Crimper EC 65 Date of issue 08 2016 Keep for future use...
Page 34: ......
Page 36: ......
Page 63: ...EC 65 Mode d emploi Sertisseuse lectrique EC 65 Edition 08 2016 A conserver...
Page 64: ......
Page 66: ......