background image

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
GLP® impression S350 User Manual Revision A 
This user manual covers fixture software version v. 28-40-28-27 
 

© 2018 German Light Products GmbH. All rights reserved. 
The marks ‘GLP’, ‘German Light Products’ and ‘impression’ are trademarks registered as the property 

of German Light Products GmbH in Germany, in the United States of America and in other countries. 
The information contained in this document is subject to change without notice. German Light 
Products GmbH and all affiliated companies disclaim liability for any injury, damage, direct or 

indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to 

use or reliance on the information contained in this document. 
Manufacturer head office: 

German Light Products GmbH (GLP), Industriestrasse 2, 76307 Karlsbad, Germany 

Tel (Germany): +49  7248  92719 - 0 
Service & Support EMEA: 

GLP, Industriestrasse 2, 76307 Karlsbad, Germany 

Tel. (Germany): +49  7248  9271955 
Email: [email protected] 

www.glp.de 
Service & Support USA: 
GLP USA, 1145 Arroyo St., Ste. A, 91340 San Fernando, California 

Tel (USA): +1  818  767  8899 
Support (US): [email protected] 

www.germanlightproducts.com 

 

 

Summary of Contents for impression s350

Page 1: ...User Manual Software v 28 40 28 27...

Page 2: ...l affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the in...

Page 3: ...uct overview 11 4 Product features 12 5 Preparation for use 19 6 Control menus and LCD display 23 7 Control menu layout 25 8 DMX channel layout 29 9 Caring for your product 36 10 Troubleshooting 37 11...

Page 4: ...using the product The manufacturer will take no responsibility for damages or harm resulting from disregard for the information in this manual Check the GLP website at www glp de and make sure that yo...

Page 5: ...e carrying out any installation or maintenance work and when the product is not in use Disconnect the product from power immediately if the power plug or any seal cover cable or other component is dam...

Page 6: ...If the fixture seems to be abnormally hot shows signs of melting or emits smoke disconnect the fixture from power immediately and allow it to cool Do not touch the fixture without heatproof safety glo...

Page 7: ...ure must be installed and operated by qualified personnel only and in accordance with applicable regulations such as DIN VDE 0711 217 The fixture is not portable when installed Ensure that the support...

Page 8: ...cal component Restrict access below the work area and work from a stable platform whenever installing servicing or moving the product If the product becomes damaged stop using it immediately and disco...

Page 9: ...fixture is shielded or points away from the sun even when not in use Avoid pointing other high powered beam lights directly at the fixture Do not pick up or carry the fixture by the front lens bezel a...

Page 10: ...l packaging to protect the fixture from damage caused by shocks during transportation Store the fixture in a dry location where the temperature will remain above 0 C 32 F when not in use Important All...

Page 11: ...D Tripod stand supplied E Stabilizing strap attachment point F Yoke cooling vents G Tilt lock H Yoke cooling vents I Control panel display J Mode button K Jog wheel L Enter button M DMX Out thru 5 pin...

Page 12: ...ent damage from direct sunlight It may be placed upright on a level surface or suspended from a suitable structure as described this manual The impression S350 is not suitable for household use for us...

Page 13: ...DMX channel lets you adjust color temperature from 8 000 K to 2500 K by deploying the CMY flags The channel sets the flags into the perfect positions for matching color temperatures on the black body...

Page 14: ...er select a fixed gobo or set the entire fixed gobo wheel to rotate with variable speed and direction on DMX channel 13 Animation wheel You can deploy the animation wheel with the animation profile at...

Page 15: ...e 1 To use framing select either PI mode this mode is selected by default or LR mode using either the fixture s control panel or the Special Control DMX channel Then use DMX channels 25 32 to control...

Page 16: ...tion distance ranges Four focus tracking settings are available Focus tracking OFF sets the zoom and focus DMX channels to control zoom and focus completely independently of each other Focus tracking...

Page 17: ...onstant at ambient temperatures of up to 45 C 113 F Intensity is smoothly limited further if it becomes necessary in order to keep fixture temperature at optimum level Fan constant low mode sets fans...

Page 18: ...use this setting if you want fixtures to automatically start stand alone operation when you apply power to them PWM frequency You can change the LED dimming PWM frequency in order to avoid flicker an...

Page 19: ...nstructions in this chapter or placed on a level surface in locations where it is safe to stand the fixture Keep the head at least 0 2 m 8 in away from combustible materials including curtains and sta...

Page 20: ...chment on page 20 Make sure that the head will not collide with another fixture or any other object when it moves through its full pan and tilt ranges Safety attachment If the impression S350 may caus...

Page 21: ...power at any other voltage or to an external dimmer The impression S350 has a 3 conductor Neutrik powerCON TRUE1 socket that accepts AC power from a Neutrik powerCON TRUE1 female cable connector Alth...

Page 22: ...completely shut down even though power is applied the main fuse may have blown Disconnect the fixture from power before replacing the fuse You can open the fuseholder with a flat headed screwdriver Re...

Page 23: ...LCD display provide access to user settings readouts and utilities When power is applied the fixture resets and impression S350 appears in the display panel After the reset has completed the main menu...

Page 24: ...ture s DMX start address is 101 it uses DMX channels 101 135 and DMX channel 136 is available for use as the start address of the next device on the DMX link A flashing display indicates loss of DMX T...

Page 25: ...aming control mode to Left Right No DMX Blackout Fixture blacks out if DMX signal stops Hold Fixture continues to display current effect if DMX signal stops Stand Alone Fixture displays its stand alon...

Page 26: ...rn fixture to factory default settings Temperature LED XXX LED PCB temperature Temperature main XXX Main PCB temperature Temperature base XXX Base PCB temperature Boot count XXX Number of startups sin...

Page 27: ...Position offs Frost offset RotGob Pos Offset RotGob Pos Compens RotGob Rot Offset EffectWhl Pos Offs FixGobo offset ColorWheel offset Cyan Offset Cyan Offset fine Magenta Offset Magenta Offset fine Y...

Page 28: ...edback Reverse Pan ON OFF Invert Pan Reverse Tilt ON OFF Invert Tilt Reverse Zoom ON OFF Invert Zoom from Wide Spot to Spot Wide Reset Pan Tilt only ON OFF Reset Pan and Tilt Reset head only ON OFF Re...

Page 29: ...36 39 40 43 44 167 168 211 212 213 255 0 0 1 2 1 6 2 7 3 1 4 3 4 7 5 9 6 3 7 5 7 8 9 0 9 4 10 6 11 0 12 2 12 5 13 7 14 1 15 3 15 7 16 9 17 3 65 5 65 9 82 7 83 1 83 5 100 Snap Snap Snap Snap Snap Snap...

Page 30: ...180 183 184 187 188 191 192 195 196 199 200 203 204 207 208 211 212 215 216 219 220 223 224 227 228 231 232 235 236 239 240 243 244 247 248 251 252 255 47 1 48 2 48 6 49 8 50 2 51 4 51 8 52 9 53 3 54...

Page 31: ...obo wheel rotation stop 192 75 3 Snap Gobo wheel rotation CCW slow fast 193 255 75 7 100 Fade 11 Gobo wheel 1 index rotation Gobo index 0 360 0 32767 0 0 50 0 Fade Gobo rotation CW fast slow 32768 491...

Page 32: ...nap Gobo wheel rotation CW fast slow 129 191 50 6 74 9 Fade Gobo wheel rotation stop 192 75 3 Snap Gobo wheel rotation CCW slow fast 193 255 75 7 100 Fade 14 Shutter Closed 0 15 255 0 5 9 Snap Pulse r...

Page 33: ...ndexing CW indexing from 0 to 45 Center 0 CCW indexing from 0 to 45 0 128 128 129 255 128 0 50 2 50 2 50 6 100 Fade Snap Fade 25 Framing blade 1 position left PI mode In out LR mode Blade left side 0...

Page 34: ...66 68 69 71 72 74 75 77 78 80 81 83 84 86 87 89 90 92 93 95 96 98 99 104 105 107 108 110 111 113 114 116 117 119 120 122 123 125 126 128 129 131 132 134 141 143 144 146 147 149 150 152 153 158 159 161...

Page 35: ...by 2 56 and rounding to the nearest 0 1 To apply a command on Channel 33 Special Control start at a value of zero then move to the required value and hold it for the required time e g 3 seconds If you...

Page 36: ...ou expect Draw up a cleaning schedule that will make sure that dirt is removed before it can build up Use the following guidelines Disconnect the fixture from power and allow it to cool completely bef...

Page 37: ...d is disturbing data transmission on the link Inspect connections and cables Correct poor connections Repair or replace damaged cables Insert DMX termination plug in data output socket of last fixture...

Page 38: ...filter soft heavy Animation effects Rotating animation wheel 0 90 indexable wheel angle Dimmer 0 100 continuous electronic 16 bit choice of two dimming curves Shutter strobe Instant open and blackout...

Page 39: ...load 5 pin XLR Art Net firmware upload EtherCon Electrical AC power 100 240 V 50 60 Hz Maximum power consumption 230 V 550 W Minimum power consumption all effects static zero light output 80 W typical...

Page 40: ...U power cable 16 A 1 5 mm H05VV F 1 5 m Detachable tripod floor stand Shipping options Single product Cardboard packing case Tour packs 2 fixture flightcase Dimensions and weight Depth head horizontal...

Page 41: ...German Light Products GLP impression S350 User Manual 41 12 Dimensions...

Page 42: ...re that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of GLP products This product contains a lithium battery Ensure that it is...

Page 43: ......

Page 44: ......

Reviews: