background image

 

3

3

3

0

0

0

0

0

0

 

 

 

X

X

X

L

L

L

 

 

 

R

R

R

Z

Z

Z

 

 

 

R

R

R

G

G

G

B

B

B

 

 

GLP 

 German Light Products GmbH 

(Manual Version 1.2) / from Software Version 1.01/03/02)

 

17

 

c)  Standard Mode (Hold down the ENTER- button during power ON)  

After switching on the fixture, the DMX start address will be set to [001]. All other settings 

will remain unchanged.  

 

Additional Display Indications  

As a default you'll find the following additional information in the first row of the LCD display:  

XX/X/XX 
 

06 = 600Hz / 12 = 1200Hz 

 

N = Normal Mode / C = Compressed Mode / H = High Res. Mode 

 

N = Tilt normal / I = Tilt inverted  

 

N = Pan normal  / I = Pan inverted  

 

5

5

 

  Maintaining and Cleaning the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

3

3

0

0

0

0

 

 

X

X

L

L

 

 

R

R

Z

Z

 

 

R

R

G

G

B

B

 

 

 

 

The 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

3

3

0

0

0

0

 

 

X

X

L

L

 

 

R

R

Z

Z

 

 

R

R

G

G

B

B

 

 is a low maintenance fixture. It is only necessary 

to clean the air inlets and outlets as well as the optical LED lenses from time to time. 

For safe operation it is absolutely essential that the fixture is kept clean and that dust, 

dirt  and  smoke-fluid  residues  must  not  build up  on,  or  within,  the fixture.  If  they  do, 

the fixture's light output will be significantly reduced, and damages to the fixture may 

occur.  Regular  cleaning  will  not  only  ensure the maximum  light  output, but  will  also 

allow the fixture to operate reliably throughout its entire life.  

A  soft  lint-free  cloth  moistened  with  any  good  glass  cleaning  fluid  is  recom-

mended. Under no circumstances should alcohol or solvents be used to clean 

the fixture or its lenses! 

5.1  Safety regulations 

 

Disconnect the fixture from the mains power before commencing any maintenance 

work! 

 

Wait minimum 15 minutes after removing the power to allow the fixture to cool down. 

5.2  Maintenance Intervals (rule-of-thumb) 

The maintenance schedule of any given fixture depends on the installation environment. Hence 

no specific guidelines can be given. The cleaning intervals given below are suggestions, based 

on  practical  experience.  We  suggest  that  you  start  with  these  and  develop  your  own 

maintenance schedule as you see the fixtures performance in your specific environment.  

Maintenance Task 

Interval 

How 

Cleaning  of  LED  lenses  and 
optical system 

weekly 

soft brush /lint-free cloth 

Cleaning of fans and air channels 

monthly 

vacuum cleaner, airbrush, etc. 

Summary of Contents for Impression 300 XL RZ RGB

Page 1: ...Instruction Manual from Software Version 1 01 03 02 Manual Version 1 2 e mail service glp de Internet http www glp de...

Page 2: ...3 3 30 0 00 0 0 X X XL L L R R RZ Z Z R R RG G GB B B GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 2 For your notes...

Page 3: ...6 2 1 1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9...

Page 4: ...to secure and lock the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system Safety eyelets 1 2 4 5 3 base side 1 10 6 7 8 9 10 base side...

Page 5: ...d the manufacturers warranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the...

Page 6: ...ation and Installation 2 1 Mounting The I IM MP PR RE ES SS SI IO ON N 3 30 00 0 X XL L R RZ Z R RG GB B is fully operational whether it hangs or is mounted to a wall It can also be operated while sta...

Page 7: ...sing the two Camlock quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to re...

Page 8: ...available from GLP or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is...

Page 9: ...32mm Please see printing on the case for the correct mains supply Disconnect from the mains supply for changing the fuse and use only the above described micro fuse type 2 3 2 DMX USITT DMX 512 Standa...

Page 10: ...blue Green Manual control for green DOWN UP Red Manual control for red Color Wheel Manual control for the color wheel Tilt Manual control for Tilt Y movement Zoom Manual control for Zoom Display Cont...

Page 11: ...cally position feedback correction for Pan Tilt movement White Adjust Adjustments for a uniform white color white balance only in white mode Red Input for red adjustments DOWN UP Blue Input for blue a...

Page 12: ...Tilt SelectsInverse Tilt on or off Reset RESET all functions 4 DMX Channel Sheet Normal Mode 14 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 0 255 00 FF 0 100 2 PAN fine Hi...

Page 13: ...ast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 255 F0 FF 95 100 10 Dimmer Dimmer 0 100 0 255 0 FF 0 100 11 Color No color temperature correction 0 0 0 temperature Continuous color temperature cor...

Page 14: ...xists to likewise select these settings also in the display menu If the White Mode is set to ON the white balance is activated If the White Mode is set to OFF the RGB goes for the maximum light output...

Page 15: ...ing then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 249 F0 F9 9...

Page 16: ...nbow effect synchronously Different I IM MP PR RE ES SS SI IO ON N 3 30 00 0 X XL L R RZ Z R RG GB B can have different start colors but will still execute the rainbow effect synchronously If you choo...

Page 17: ...ld up on or within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output b...

Page 18: ...System Additive Color mixing LED Type 297x Luxeon Rebel High power LEDs Lifetime 50 000 h 105 red 96 green 96 blue LEDs wavelength optimized for maximum presentable color space Optical System High ef...

Page 19: ...1 K Key code 10 L LED Class 2M 5 M Maintenance 17 Manual Version 1 Max Power Mode 14 Micro fuse 9 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the F...

Page 20: ...3 3 30 0 00 0 0 X X XL L L R R RZ Z Z R R RG G GB B B GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 20...

Reviews: