background image

 

3

3

3

0

0

0

0

0

0

 

 

 

X

X

X

L

L

L

 

 

 

R

R

R

Z

Z

Z

 

 

 

R

R

R

G

G

G

B

B

B

 

 

GLP 

 German Light Products GmbH 

(Manual Version 1.2) / from Software Version 1.01/03/02)

 

5

 

1.1 

Safety Instructions  

 

 

The

 

 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

3

3

0

0

0

0

 

 

X

X

L

L

 

 

R

R

Z

Z

 

 

R

R

G

G

B

B

 

 

is  an  advanced  technology  product. 

To  guarantee  smooth  operation,  it  is  necessary  to  follow  the  following 
instructions. 

The  manufacturer  of  this  device  will  not  take  responsibility  of  damages 
through any disregard of the information in this user manual. Warranty claims 
will also be cancelled in the event of the system casing being opened. 

1.  Make  sure  that  before  powering  up  the  fixture,  the  fans  and  air  inlets  are 

clean and not blocked by anything. 

2.  Before  powering  up  the  fixture,  ensure  that  the  moving  head  part  of  the 

fixture can rotate unhindered through its full range of movement.  

3.  A  safety  distance  of  at  least  0.5  m  to  any  easily  flammable  material  (e.g. 

decoration material) must be adhered to.  

4.  Attention! Don’t touch the device during operation. Parts of the fixture can 

become hot and can cause injuries and / or damages.  

5.  The system doesn’t contain any user serviceable parts. Opening the fixture 

will void the manufacturers warranty. 

6.  Danger  of  burning.  Wait  at  least  15  minutes  after  disconnecting  the  AC 

power  before  changing  the  optical  carrier  on  the  fixture.  Pay  attention  to 

possible hot parts of the system. 

7. 

Never look directly into the beam of light or one of the LEDs. Never use 

optical  apertures  with  a  distance  less  than  0.5  m  to  observe  the  beam  of 

light. LED Class 2M. Not following these precautions can result in serious 

injury to your eyes and in particular, your retina.  

  

 

Attention: LED Class 2M can cause injuries of your eyes even 
without optical instruments in front of them or within a distance 
of less than 0.5m and short exposure time.   

 

Avoid direct radiation to your eyes!   

8.  To  ensure  proper  operation,  you  must  also  follow  the  installation  guide 

described in chapter 2 of this manual. Operating the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

3

3

0

0

0

0

 

 

X

X

L

L

 

 

R

R

Z

Z

 

 

R

R

G

G

B

B

 

  without  suitable  mounting  devices  can  increase  the  risk  of  an 

accident. 

9.  The 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

3

3

0

0

0

0

 

 

X

X

L

L

 

 

R

R

Z

Z

 

 

R

R

G

G

B

B

 

 features a unique small and lightweight 

design  with  no  specific  carrying  handles.  Care  needs  to  be  shown  when 

handling  the  fixture  to  ensure  that  no  unnecessary  damage  should  occur. 

Fragile  areas  include  the  LCD  display  and  cover  on  one  side arm and  the 

front bezel. Pressure in these areas could result in damages which will not 

Summary of Contents for Impression 300 XL RZ RGB

Page 1: ...Instruction Manual from Software Version 1 01 03 02 Manual Version 1 2 e mail service glp de Internet http www glp de...

Page 2: ...3 3 30 0 00 0 0 X X XL L L R R RZ Z Z R R RG G GB B B GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 2 For your notes...

Page 3: ...6 2 1 1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9...

Page 4: ...to secure and lock the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system Safety eyelets 1 2 4 5 3 base side 1 10 6 7 8 9 10 base side...

Page 5: ...d the manufacturers warranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the...

Page 6: ...ation and Installation 2 1 Mounting The I IM MP PR RE ES SS SI IO ON N 3 30 00 0 X XL L R RZ Z R RG GB B is fully operational whether it hangs or is mounted to a wall It can also be operated while sta...

Page 7: ...sing the two Camlock quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to re...

Page 8: ...available from GLP or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is...

Page 9: ...32mm Please see printing on the case for the correct mains supply Disconnect from the mains supply for changing the fuse and use only the above described micro fuse type 2 3 2 DMX USITT DMX 512 Standa...

Page 10: ...blue Green Manual control for green DOWN UP Red Manual control for red Color Wheel Manual control for the color wheel Tilt Manual control for Tilt Y movement Zoom Manual control for Zoom Display Cont...

Page 11: ...cally position feedback correction for Pan Tilt movement White Adjust Adjustments for a uniform white color white balance only in white mode Red Input for red adjustments DOWN UP Blue Input for blue a...

Page 12: ...Tilt SelectsInverse Tilt on or off Reset RESET all functions 4 DMX Channel Sheet Normal Mode 14 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 0 255 00 FF 0 100 2 PAN fine Hi...

Page 13: ...ast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 255 F0 FF 95 100 10 Dimmer Dimmer 0 100 0 255 0 FF 0 100 11 Color No color temperature correction 0 0 0 temperature Continuous color temperature cor...

Page 14: ...xists to likewise select these settings also in the display menu If the White Mode is set to ON the white balance is activated If the White Mode is set to OFF the RGB goes for the maximum light output...

Page 15: ...ing then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 249 F0 F9 9...

Page 16: ...nbow effect synchronously Different I IM MP PR RE ES SS SI IO ON N 3 30 00 0 X XL L R RZ Z R RG GB B can have different start colors but will still execute the rainbow effect synchronously If you choo...

Page 17: ...ld up on or within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output b...

Page 18: ...System Additive Color mixing LED Type 297x Luxeon Rebel High power LEDs Lifetime 50 000 h 105 red 96 green 96 blue LEDs wavelength optimized for maximum presentable color space Optical System High ef...

Page 19: ...1 K Key code 10 L LED Class 2M 5 M Maintenance 17 Manual Version 1 Max Power Mode 14 Micro fuse 9 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the F...

Page 20: ...3 3 30 0 00 0 0 X X XL L L R R RZ Z Z R R RG G GB B B GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 20...

Reviews: