 MODE - ENTER 

 

 

 

Level1 

Level 2 

Level 3 

Level 4 

Remark 

 

DMX Start 
Address 
001 

 

 

 

Define the DMX start address 

 

Special 

Manual DMX 

 

 

Manual control of all system functions 

 

 

 

Pan 

 

Manual control for Pan (X-movement)  

 

 

 

Speed 
Movements 

 

Speed adjustment for Pan/Tilt movements 

 

see also item below 

 

 

 

Pan/Tilt 
Movements 

 

Manual control for Pan/Tilt movement 

 

 

 

Special 

 

Activate the White- or Full-Power Mode; see 
also DMX table 

 

 

 

White 
Temperature 

 

Adjustment of the white color temperature  

 

 

 

Dimmer 

 

Manual control for dimmer  

 

 

 

Shutter 

 

Manual control for shutter 

 

 

 

Blue 

 

Manual control for blue 

 

 

 

Green 

 

Manual control for green 

 D

O

W

N

  

 U

P

 

 

 

 

Red 

 

Manual control for red 

 

 

Color Wheel 

 

Manual control for the color wheel 

 

 

Tilt 

 

Manual control for Tilt (Y-movement)  

 

 

Zoom 

 

Manual control for Zoom 

 

Display 
Contrast 

 

 

Adjustment for the Display contrast  

 

Default Set 

 

 

Resetting all functions to original values 

 

 

Set Dimmer 
Frequency 

 

 

Changes PMW frequency between 600Hz and 
1200Hz 

 

 

LED Dimmer 
Version 

 

 

Reads out the current LED dimmer (software) 
version 

 

 

ImpressionXL 
300 Version 

 

 

Reads out the current CPU software version 

 

 

Adjust 

Key code 
xxxx 

 

Use the code for entering the calibration menu 
(for authorized persons only)  

 

 

 

Pan Offset 

 

Calibration for Pan-Offset 

 

 

 

Tilt Offset 

 

Calibration for Tilt-Offset 

 

 

 

Clear 
EEPROM 

 

Erase EEPROM memory 

 

 

 

Diagnose 

 

Diagnose functions 

 

 

 

 

Pos Feed Pan 
Delta 

Internal data and function diagnose 

 

 

 

 

Anz Ti0-Int-
Err 

Internal data and function diagnose 

 

 

 

 

PFC Voltage 

Show the present PFC voltage 

Summary of Contents for Impression 300 XL RZ RGB

Page 1: ...Instruction Manual from Software Version 1 01 03 02 Manual Version 1 2 e mail service glp de Internet http www glp de...

Page 2: ...3 3 30 0 00 0 0 X X XL L L R R RZ Z Z R R RG G GB B B GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 2 For your notes...

Page 3: ...6 2 1 1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9...

Page 4: ...to secure and lock the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system Safety eyelets 1 2 4 5 3 base side 1 10 6 7 8 9 10 base side...

Page 5: ...d the manufacturers warranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the...

Page 6: ...ation and Installation 2 1 Mounting The I IM MP PR RE ES SS SI IO ON N 3 30 00 0 X XL L R RZ Z R RG GB B is fully operational whether it hangs or is mounted to a wall It can also be operated while sta...

Page 7: ...sing the two Camlock quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to re...

Page 8: ...available from GLP or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is...

Page 9: ...32mm Please see printing on the case for the correct mains supply Disconnect from the mains supply for changing the fuse and use only the above described micro fuse type 2 3 2 DMX USITT DMX 512 Standa...

Page 10: ...blue Green Manual control for green DOWN UP Red Manual control for red Color Wheel Manual control for the color wheel Tilt Manual control for Tilt Y movement Zoom Manual control for Zoom Display Cont...

Page 11: ...cally position feedback correction for Pan Tilt movement White Adjust Adjustments for a uniform white color white balance only in white mode Red Input for red adjustments DOWN UP Blue Input for blue a...

Page 12: ...Tilt SelectsInverse Tilt on or off Reset RESET all functions 4 DMX Channel Sheet Normal Mode 14 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 0 255 00 FF 0 100 2 PAN fine Hi...

Page 13: ...ast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 255 F0 FF 95 100 10 Dimmer Dimmer 0 100 0 255 0 FF 0 100 11 Color No color temperature correction 0 0 0 temperature Continuous color temperature cor...

Page 14: ...xists to likewise select these settings also in the display menu If the White Mode is set to ON the white balance is activated If the White Mode is set to OFF the RGB goes for the maximum light output...

Page 15: ...ing then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 249 F0 F9 9...

Page 16: ...nbow effect synchronously Different I IM MP PR RE ES SS SI IO ON N 3 30 00 0 X XL L R RZ Z R RG GB B can have different start colors but will still execute the rainbow effect synchronously If you choo...

Page 17: ...ld up on or within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output b...

Page 18: ...System Additive Color mixing LED Type 297x Luxeon Rebel High power LEDs Lifetime 50 000 h 105 red 96 green 96 blue LEDs wavelength optimized for maximum presentable color space Optical System High ef...

Page 19: ...1 K Key code 10 L LED Class 2M 5 M Maintenance 17 Manual Version 1 Max Power Mode 14 Micro fuse 9 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the F...

Page 20: ...3 3 30 0 00 0 0 X X XL L L R R RZ Z Z R R RG G GB B B GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 20...

Reviews: