Introduction
WARNING:
It is important that the case (not the controls tray)
is not disturbed or removed other than for servicing by a
competent person.
Please read these instructions and follow them carefully for the
safe and economical use of your boiler.
The Micron FF series are fanned flue boilers designed to
provide central heating and indirect domestic hot water.
The boiler is fully automatic in operation having only one user
control, the control thermostat.
Gas Leak or Fault
Turn off the gas emergency control valve immediately. Eliminate
all sources of ignition, i.e. smoking, blowlamps, hot air guns etc.
Do not operate electrical lights or switches either on or off. Open
all doors and windows, ventilate the area.
Electrical Supply Failure
Failure of the electrical supply will cause the burner to go out.
Should this occur, operation of the appliance will normally
resume after the electrical supply is restored.
If the boiler does not relight after an electrical supply failure the
overheat safety cutoff device may need resetting, remove the
controls cover and press the reset button, refer to diagram 8.1.
Overheat Safety Cutoff
If the overheat safety cutoff device operates on any other
occasion than an electrical supply failure, press the reset button
as in “Electrical Supply Failure”. If the overheat operates again,
turn the appliance off and contact your installation/servicing
company.
Maintenance
To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
depend upon the particular installation conditions and usage,
but in general once a year should be enough.
If this appliance is installed in a rented property in the UK there
is a duty or care imposed on the owner of the property by the
current issue of The Gas Safety (Installation and Use)
Regulations, Section 35.
It is the law that any servicing is carried out by a
competent
person.
To obtain service, please call your installer or Glow-worm’s own
Service Organisation using the telephone number given on the
controls tray.
Please be advised that the ‘Benchmark’ logbook should be
completed by the installation engineer on completion of
commissioning and servicing.
All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boiler Logbook. You can check your installer is CORGI registered
by calling CORGI direct on :- 01256 372300.
Boiler Clearances
If fixtures are positioned close to the boiler space must be left
as shown in diagram 1.2. At least a minimum clearance of
500mm must be left in front of the boiler to allow for servicing.
Boilers Installed in a Compartment or
Cupboard
If the boiler is installed in a compartment or cupboard do not
obstruct any ventilation openings.
Do not use the compartment or cupboard for storage.
Cleaning
WARNING:
This appliance contains metal parts (components)
and care should be taken when handling and cleaning, with
particular regard to edges.
Clean the casing occasionally by wiping it over with a damp
cloth or dry polishing duster.
Do not use an abrasive cleaner.
Boiler Electrical Supply
WARNING:
This boiler must be earthed.
The boiler must only be connected to a 230V~50Hz supply
protected by a 3A fuse.
All wiring must be in accordance with the current issue of
BS7671.
Wiring to the boiler must be PVC insulated type to the current
issue of BS6500 Table 16, not less than 0.75mm
2
(24/0.20mm).
The colours of three core flexible cable are:
Brown - live, Blue - neutral,
Green/yellow - earth.
As the markings on your plug may not correspond with these
colours continue as follows:
The cable coloured blue must be connected to the terminal
marked “N” or black.
The cable coloured brown must be connected to the terminal
marked “L” or red.
The cable coloured green/yellow must be connected to the
terminal marked “E”, or green or the earth symbol
.
Instructions for Use