Glow-worm Envirosorb 10 Instructions For Use Manual Download Page 6

www.glow-worm.co.uk

6

1.2 Testing and Certification

This appliance is certificated for performance and safety in use. 
It is important that no alteration is made to the appliance unless 

approved, in writing, by Glow-worm.
Any alteration not approved by Glow-worm, could invalidate 

the certification, appliance warranty and may also infringe the 

current issue of the statutory requirements.

1.3 CE Mark

The CE mark on this appliance shows compliance with:
1.   Directive 97/23/EEC on pressure equipment
2.   Directive 73/23/EEC on the harmonisation of the Laws of the 

Member States relating to electrical equipment designed for use 

within certain voltage limits.
3.   Directive 89/336/EEC on the approximation of the Laws of 

the Member States relating to electromagnetic compatibility.

1.4 General Note

Servicing/maintenance should be carried out by a competent 

person in accordance with the rules in force in the countries of 

destination.

1.5 Servicing

This appliance should be serviced regularly to optimise its 

safety, efficiency and performance.  
To ensure the continued efficient and safe operation of the 

appliance it is recommended that it is checked and serviced at 

regular intervals. The frequency of servicing will depend upon 

the site conditions and usage, but in general, once a year should 

be enough.
To obtain service, please call your installer or Glow-worm’s own 

service organisation using the telephone number on the inside 

front cover of this booklet.

1.6 Spare Parts

REMEMBER:

 When replacing a part on this appliance, use 

only spare parts that you can be assured conform to the 

safety and performance specification that we require. Do not 

use reconditioned or copy parts that have not been clearly 

authorised by Glow-worm.
If replacement parts are required contact Glow-worm’s own 

service organisation using the telephone number on the 

inside front cover of this booklet.
Please quote the name and model of the appliance. The 

name and model badge is on the outer case above the 

hydraulic connections.
If in doubt seek advice from Glow-worm’s own service 

organisation using the telephone number on the inside front 

cover of this booklet.

1  Your safety

Summary of Contents for Envirosorb 10

Page 1: ...To b e l e f t w i t h t h e u s e r www glow worm co uk Instructions for Use www glow worm co uk Air Water Heat Pump Envirosorb...

Page 2: ...es Under no circumstances must the User interfere with or adjust sealed parts WARNING Benchmark places responsibilities on both manufacturers and installers The purpose is to ensure that customers are...

Page 3: ...www glow worm co uk 3 Envirosorb 8 Envirosorb 10 Envirosorb 14 15410 30 psi bar 20 40 10 0 4 1 3 2 50 58...

Page 4: ...Page Your Safety 1 5 Maintenance 2 7 Design description 3 8 Display 4 9 Adjustments 5 12 Operating Instructions 6 14 Service Indicator Description 7 17 Maintenance 8 18 Disposal 9 20 Fault Code Descri...

Page 5: ...ppliances installation manual and in the user manual 1 Your safety In the event that the heat pump is removed and subsequently reinstalled its proper reinstallation must be adequately verified Otherwi...

Page 6: ...regularly to optimise its safety efficiency and performance To ensure the continued efficient and safe operation of the appliance it is recommended that it is checked and serviced at regular interval...

Page 7: ...e external heat exchanger inlet surface Occasionally check the base of the Envirosorb to ensure to the drain pan is clean and there is no build up of corrosion DANGER of injury and physical damage Do...

Page 8: ...Fully sealed refrigeration system utilising non ozone depleting R410a refrigerant In built hydraulic module consisting of pump heat exchanger expansion vessel air vent and pressure gauge Low noise le...

Page 9: ...ture or Water outlet temperature display Time of programming period 3 Timer status display 4 Time of programming period 5 Days of the week display 6 On Off status display Display function Number 7 Ope...

Page 10: ...espectively and For switching off the appliance or validating input 4 2 WARNING SYMBOLS Equipment shut down warning ERR C F ERR AM PM AM PM 6 7 12 Off Set The control can show a series of alpha numeri...

Page 11: ...sly or timer delay on or off using the delay timer On Mode Off Set AM PM 1 2 3 4 5 6 7 C F LOW BAT ON OFF TIMER ON OFF Programmable Mode unit operates only for the user set timed periods Press the On...

Page 12: ...f Set AM PM 1 2 3 4 5 6 7 C F LOW BAT ON OFF TIMER ON OFF key or go to the next function using the On Mode Off Set AM PM 1 2 3 4 5 6 7 C F LOW BAT ON OFF TIMER ON OFF key 5 3 OPERATING MODE On Mode Of...

Page 13: ...de Off Set AM PM 1 2 3 4 5 6 7 C F LOW BAT ON OFF TIMER ON OFF Only available when control set as inside thermostat Shows the room temperature On Mode Off Set AM PM 1 2 3 4 5 6 7 C F LOW BAT ON OFF TI...

Page 14: ...MM AM PM for start up Confirm by pressing On Mode Off Set AM PM 1 2 3 4 5 6 7 C F LOW BAT ON OFF TIMER ON OFF Press On Mode Off Set AM PM 1 2 3 4 5 6 7 C F LOW BAT ON OFF TIMER ON OFF to switch the un...

Page 15: ...e Off Set AM PM 1 2 3 4 5 6 7 C F LOW BAT ON OFF TIMER ON OFF The start up time flashes The start up time must ALWAYS be earlier than the stop time Using the and arrows select the start up time for ex...

Page 16: ...ys the next block is started These must be different days to the previous setting Example Programming 1 Monday to Friday from 7 00 to 13 00 and from 16 00 to 20 00 Programming 2 Saturday from 10 00 to...

Page 17: ...n F0 This flashes at around 2000 operational hours of the pump to indicate that it is necessary to clean the filter F3 In heating mode at an outside temperature of 7 C the pressure reached is higher t...

Page 18: ...locked status If after replacing the batteries the control remains with a blank screen press to activate it NOTE reprogramming may be required after replacing batteries WARNING Potentially dangerous...

Page 19: ...appliance for a while never disconnect the circuit breaker The appliance must always have a power supply If the power supply is disconnected the pump anti freeze and anti wear protection devices cann...

Page 20: ...en you dispose of it Dispose of the equipment in accordance with the relevant local and national standards correctly and in an enironmentally friendly way Do not put the appliance with other domestic...

Page 21: ...unication between the interface and the main circuit board c2 Main circuit board fault c5 Floor temperature sensor fault where fitted accessory c7 Ambient humidity sensor fault where fitted accessory...

Page 22: ...cking noise may be heard This noise is generated as a result of the expanding or contracting of the housing caused by changes in temperature of the different materials and is quite normal Noise is hea...

Page 23: ...www glow worm co uk 23...

Page 24: ...gh efficiency info Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions Glow worm Nottingham Road Belper Derbyshire DE56 1JT 0020084984 02...

Reviews: