7 Service Indicator Description
15333
7.1 Equipment inspection warning
On/
/Mode
Off/
/Set
AM
PM
1 2 3 4 5 6 7
°C
°F
LOW
BAT
ON
OFF
TIMER
ON OFF
°C
°F
ERR
AM
PM
AM
PM
ON
OFF
1 2 3 4 5 6 7
LOW
BAT
TIMER
ON OFF
11
On/
/Mode
Off/
/Set
When an "F" and a number is flashing, servicing is necessary.
Service indicators do not cause a shut down of the system.
When one of the "F" codes is flashing the symbol
On/
/Mode
Off/
/Set
AM
PM
1 2 3 4 5 6 7
°C
°F
LOW
BAT
ON
OFF
TIMER
ON OFF
is shown
on the control. Each time any key is pressed, the service indicator
will appear for a few seconds.
Code Description
F0
This flashes at around 2000 operational
hours of the pump to indicate that it is
necessary to clean the filter.
F3
In heating mode, at an outside
temperature of 7ºC, the pressure reached is
higher than 35 bars.
F4
In heating mode, at an outside
temperature of 20ºC, the refrigerant low
pressure is below 3 bar
F5
Water flow lacking: an initial fault has been
found. Repetition of the F5 fault will stop the
device (code h2)
F6
Antifreeze fault: an initial fault has been
found. Repetition of the F6 fault will stop the
device (code h4)
F9
The sensor measured an initial pressure
excess. 3 detections produce an h0 block-
age. An h0 code may be produced either by
3 high pressure detections in less than an
hour (P>42 bar), or by a triggering of the
pressure switch (P>42 bar).