Appendix
48
Installation and maintenance instructions ENERGY 0020177746_03
ENERGY 25c -A (H-
GB)
ENERGY 30c -A (H-
GB)
ENERGY 35c -A (H-
GB)
Gas flow at P max.
–
hot water
(G20)
2.7 m
³
/h
3.2 m
³
/h
3.8 m
³
/h
Gas flow at P max.
–
heating mode
(G20)
1.9 m
³
/h
2.7 m
³
/h
2.7 m
³
/h
Gas flow at P min. (G20)
0.540 m
³
/h
0.646 m
³
/h
0.762 m
³
/h
CE number (PIN)
CE-0063CP3646
CE-0063CP3646
CE-0063CP3646
Flue gas mass rate in heating
mode at P min.
2.34 g/s
2.80 g/s
3.30 g/s
Flue gas mass rate in heating
mode at P max.
8.3 g/s
11.5 g/s
11.6 g/s
Flue gas mass rate in hot water
handling mode at P max.
11.6 g/s
13.8 g/s
16.1 g/s
Flue gas temperature (80 °C/60 °C)
at P max.
60
℃
77
℃
82
℃
Flue gas temperature (80 °C/60 °C)
at P min.
55
℃
55
℃
56
℃
Flue gas temperature (50 °C/30 °C)
at P max.
51
℃
62
℃
56
℃
Flue gas temperature (50 °C/30 °C)
at P min.
34
℃
35
℃
37
℃
Flue gas temperature in hot water
handling mode
69
℃
68
℃
75
℃
Flue gas temperature when over-
heating
105
℃
95
℃
104
℃
Released system types
C13, C33, C43
C13, C33, C43
C13, C33, C43
Nominal efficiency at 80/60 °C
99.6 %
99.6 %
99.6 %
Nominal efficiency at 50/30 °C
104.0 %
104.0 %
104.0 %
Nominal efficiency at 40/30 °C
106.0 %
106.0 %
106.0 %
Nominal efficiency in partial load
operation (30%) at 40/30 °C
108.5 %
108.5 %
108.5 %
NOx class
5
5
5
Product dimensions, width
390 mm
390 mm
390 mm
Product dimensions, depth
280 mm
280 mm
280 mm
Product dimensions, height
700 mm
700 mm
700 mm
Net weight
32 kg
33 kg
33 kg
Weight when filled with water
36 kg
38 kg
38 kg
Technical data
–
Electrics
ENERGY 25c -A (H-
GB)
ENERGY 30c -A (H-
GB)
ENERGY 35c -A (H-
GB)
Electric connection
230 V / 50 Hz
230 V / 50 Hz
230 V / 50 Hz
Built-in fuse (slow-blow)
T2/2A, 250V
T2/2A, 250V
T2/2A, 250V
Max. electrical power consump-
tion
66 W
75 W
60 W
Standby electrical power con-
sumption
2 W
2 W
3 W
Level of protection
IPX4D
IPX4D
IPX4D