10 Inspection and maintenance
24
Installation and maintenance instructions ENERGY 0020177746_03
10.6
Removing the gas-air mixture unit
Note
The gas-air mixture unit consists of three main
components:
–
Fan
–
Gas valve,
–
Burner cover
1.
Switch off the product via the main switch.
2.
Close the gas isolator cock.
3.
Remove the front casing. (
→
Page 10)
C
A
B
1
D
2
4.
Remove the screw
(1)
.
5.
Push the clip upwards.
6.
Remove the flue gas pipe
(2)
.
3
4
5
A
B
7.
Remove the air intake pipe
(3)
.
8.
Remove the plugs from the gas valve
(4)
and from the
fan
(5)
.
A
C
D
B
6
9.
Remove the gas-air mixture unit
(6)
.
7
7
8
10. Remove the burner seals
(7)
and the burner
(8)
.
11. Check the burner and the heat exchanger for damage
and dirt.
12. If necessary, clean or replace the components accord-
ing to the following sections.
13. Install the two new burner seals.
10.7
Cleaning the heat exchanger
1
1.
Protect the folded down electronics box against sprayed
water.
2.
Clean the ribs of the heat exchanger
(1)
with water.
◁
The water runs out into the condensate tray.
Summary of Contents for ENERGY 25c