Appendix
46
Installation and maintenance instructions ENERGY 0020177746_03
J
Pipe lengths for the air/flue pipe
J.1
Length of the C13 type air/flue pipe
Applicability:
C13 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L)
Dia. 80/125 (L)
C13 type air/flue
pipe
C13 type air/flue
pipe
ENERGY 25c -A
(H-GB)
≤
10 m
≤
25 m
ENERGY 30c -A
(H-GB)
≤
10 m
≤
25 m
ENERGY 35c -A
(H-GB)
≤
10 m
≤
25 m
J.2
Length of the C33 type air/flue pipe
Applicability:
C33 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L)
Dia. 80/125 (L)
C33 type air/flue
pipe
C33 type air/flue
pipe
ENERGY 25c -A
(H-GB)
≤
10 m
≤
25 m
ENERGY 30c -A
(H-GB)
≤
10 m
≤
25 m
ENERGY 35c -A
(H-GB)
≤
10 m
≤
25 m
J.3
Length of the C43 type air/flue pipe
Applicability:
C43 type air/flue pipe
Diameter of the
air/flue pipe
Dia. 60/100 (L)
C43 type air/flue
pipe
ENERGY 25c -A
(H-GB)
≤
5 m
ENERGY 30c -A
(H-GB)
≤
5 m
ENERGY 35c -A
(H-GB)
≤
5 m
K
Technical data
Technical data
–
Heating
ENERGY 25c -A (H-
GB)
ENERGY 30c -A (H-
GB)
ENERGY 35c -A (H-
GB)
Max. flow temperature adjustment
range (default setting: 75 °C)
10 … 80
℃
10 … 80
℃
10 … 80
℃
Maximum permissible pressure
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
Nominal water flow (
Δ
T = 20 K)
788 l/h
1,094 l/h
1,102 l/h
Nominal water flow (
Δ
T = 30 K)
525 l/h
729 l/h
876 l/h