background image

17 

 

13 - GUIDE TO PROBLEM SOLUTION 

 
 

 

If your 

ekomille 

does not work correctly check if: 

 

  The position of the switch is high, on 

“ON” 

(see photo 10)

  The  red  led  lights  up  when  you  push  the  switch  towards  the 

bottom 

(when  it  does  not  light  up,  change  the  battery,  as 

indicated at page 12); 

 

The sensor moves freely 

(see page 14)

 

 

The  big  feed-holder  is  inserted  in  its  place  correctly 

(see  blow- 

up diagram - figure 1 - number 2)

  The  mobile  end  part  of  the  revolving  plate  is  lined  with  the  plate 

itself 

(on the contrary, remove the obstacle which does not permit 

it  - (see figure 1 - number 13); 

  The container is full and it does not allow for other capturing; 

  All  the  food  in  the  manger  has  been  eaten  while  the  device  was 

switched  off 

(in  this  case  refill  the  manger  with  new  food) 

(see 

figure 1 - number 7)

 

 

WARNING:  ekomille 

must  be  subjected  to  a  complete  maintenance  every  year.  Such 

maintenance consist of checking every mechanical and electric part. 

 

APICE srl 

is disposed to carry out the maintenance for you. 

 
 
 

 

14 - FREQUENTLY ASKED QUESTIONS 

 

a)  Why not carry on using poisons? 

 

Poisons have some disadvantages that are worth remembering: 

 

  Their efficiency is limited in time and, for this reason, they need to be used more 

than once during the year; 

  Poisons  must  become  more  powerful  every  day  because  of  the  capacity  of 

adaptation of animals; 

  We can never know where the poisoned animal will go  to die, so you can find 

the carcass anywhere; 

  Children  and  other  animals  can  be  poisoned  instead  of  mice  and  rats,  by  an 

accidental ingestion of the substances used; 

  Poisons can cause environmental pollution, by seeping through the ground and 

through the water-courses. 

Summary of Contents for Ekomille

Page 1: ...PARECCHIATURE PER IL CONTROLLO ECOAMBIENTALE INSTRUCTION MANUAL and DECLARATION of CONFORMITY Distributed by Ekommerce srl Rev 2 4En 03 09 03 Website www ekommerce it e mail ekommerce ekommerce it s r...

Page 2: ...AFETY pag 10 7 CAPTURING COUNT AND VERIFICATION pag 11 8 BATTERY AND FUNCTIONING TEST pag 12 9 MECHANISMS AND RECHARGE OF THE MOTOR SPRING pag 13 10 SENSOR pag 14 11 MACHINE CLEANING pag 14 12 ACCESSO...

Page 3: ...n the best performance and guarantee the perfect working of the device The instruction manual is an integral part of ekomille and it must follow its life cycle for ten years starting from the beginnin...

Page 4: ...y and technically safe so perfectly compatible with human domestic animal and food presence The captured animals are kept in a container in which you can decide if you want to add water together with...

Page 5: ...owards a wall or towards any other element a machinery a heap of wood or straw etc at a distance of about 10 15 cm In this way mice will have a higher feeling of protection and safety so they will eas...

Page 6: ...turns the capture of the arrived animals will be very simple Photo 1 Put ekomille with the ladder turned towards the wall or towards any other element MAXIMUM TIME OF PRESERVATION ROOM TEMPERATURE WAT...

Page 7: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Days 100 90 80 70 60 50 40 30 20 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...

Page 8: ...it along the right side of the revolving plate photo 2 mixing some seeds with it repeat the same operation for the three other revolving plates paying attention to the following instruction carefully...

Page 9: ...revolving plates Photo 4 Manger Photo 5 Big feed holder Photo 6 Little feed holder Photo 7 Food on the ladder Photo 8 Ekomille ready without cover 9 Entrance Seeds fixed with fat Rotor revolving plat...

Page 10: ...each the container b If you want to add water in the capturing container the level of the liquid must be between the signs printed inside the bucket almost 18 litres c The ekofix 40 has to be added to...

Page 11: ...le of spring recharge photo 10 WITHOUT FORCING IT after each emptying out this operation permits an easier control of the new capturing made by ekomille numbers around the handle indicate the units an...

Page 12: ...ry photo 10 if the bulb red led switches on the battery has enough power to make a capture c Remove the roof the upper container the manger the battery container plug to change it photo 11 Then detach...

Page 13: ...turn the handle in clockwise till reaching of the 0 zero either on the counter by the tens in the window or on the unit counter WITHOUT FORCING IT to recharge it photo 10 b To avoid the dechargement...

Page 14: ...towards the top to eliminate the dirtiness Photo 13 Sensor 11 MACHINE CLEANING a The container of ekomille must be cleaned only in case of bad odour Use gloves and normal products for cleaning and dis...

Page 15: ...box ekomille ekologic SPARE PARTS Rif Cod APICE Description Notes 1 APG 001 Roof 2 APG 010 Big feed holder 3 APG 008 Left covering 4 APG 009 Right covering 5 APG 013 Manger division 6 APG 011 Little f...

Page 16: ...16 Fig 1 Blow up diagram...

Page 17: ...is case refill the manger with new food see figure 1 number 7 WARNING ekomille must be subjected to a complete maintenance every year Such maintenance consist of checking every mechanical and electric...

Page 18: ...to the bottom part of ekomille capturing container in the container it is possible to add water and antiputrefaction liquid ekofix 40 The latter is also necessary to keep the device completely hygieni...

Page 19: ...will decay The repair is done exclusively at our centre where the device must arrive free on board carriage expenses are to be charged to the user unless different agreement and it does not include th...

Page 20: ...2 888058 fax 0872 888056 Website www ekommerce it e mail ekommerce ekommerce it 17 DECLARATION OF CONFORMITY The manufacturer APICE srl Zona Industriale Saletti snc 66041 Atessa CH declares and takes...