8 · GLOBE RM410 PISTON AIR MOTOR MANUAL| INCLUDING AUXILIARIES | ATEX Certified
Use only belts with <100 electrical leakage resistance to prevent static electrical
problems.
Air Inlet
The motor is normally supplied with inlet / exhaust adaptor plate (72). All motors are reversible.
Mounting to construction
»
Mount the unit to the construction. Care should be taken, when fitting drive components to the
shaft, that excessive force is not used. This will upset the shaft alignments which has been kept to a
minimum in order to give high motor performance.
»
Use the proper sized fasteners.
»
Axial loads must be kept to a minimum.
Use a puller to remove pulleys, pinions and couplings. Check if the tension on
the belt pulley matches the specifications of the manufacture. Do not exceed the
maximum radial and axial forces on the shaft. If the motor shaft is connected to the
part to be driven without a coupling, check that the radial offset and axial force
effect will not cause problems.
Maximum Working Pressure 8 bar - 120 psi
The air supply must be clean and free from moisture. An airline filter and mist lubricator should be
incorporated in the air supply line, located immediately before the motor. If the rated performance of
the motor is to be obtained all valves and pipework must be of adequate size. Valves should be
sited as close as possible to the motor. For short pipe runs e.g. up to 2 meters the supply line should
be the same size as the motor ports and larger for longer runs.
Do not exceed the maximum radial and axial forces on the shaft.
Use the proper size fasteners.
Use a puller ro remove pulleys, pinions and couplings.
STOP