Operating environment
The LB has been designed to work indoors. For this reason the reference
environmental parameters are:
temperature range b5°C and 40°C
relative humidity between 30% and 95% (without any condensation)
In addition, the place where the LB is to be operated must have the
following characteristics:
The ceiling of the area must be high enough so that any vehicle can be
lifted all the way without causing any damage.
Check this height with particular vehicles.
The support flooring must be smooth and level (free of any slope and/or
rough spots).
If the flooring is not suitable, it can prove dangerous to use the LB and
move it on the floor while loaded.
The LB cannot be used in environments with characteristics that differ from
the above.
4.5
Installation characteristics
The LB must be installed on a perfectly horizontal floor free of any bumps. The
LB must be suitably secured to the floor with the 6 screw anchors supplied with
the unit.
Operating the LB requires outside electrical and pneumatic power supplies with
the following characteristics:
electrical power supply from an industrial outlet, the voltage requirement
depends on the particular model:
240/415 V three-phase + ground and 50 Hz ± 2% frequency, rated for
a maximum 1.1 kW power absorption; the ground cable must have a
minimum section of 2.5 mm
2
;
200/230 V three-phase + ground and 50/60 ± 2% frequency, rated for a
maximum 1.1 kW power absorption; the ground cable must have a
minimum section of 2.5 mm
2
;
!!! DANGER !!!
The Customer must install a differential, three-pole safety switch with a leak
sensitivity of 30 mA upstream of the LB (in the building power supply panel) to
ensure that the power supply is automatically cut off in case of LB insulation
failure.
Summary of Contents for Evolution
Page 2: ...volution USER S MANUAL Year of Manufacture ...
Page 12: ...10 ...
Page 13: ...11 ...
Page 14: ...12 ...
Page 15: ...13 ...
Page 23: ...21 ...
Page 24: ...22 ...
Page 36: ...34 10 1 Attachment 01 Lift bench dimensions ...
Page 37: ...35 10 2 Attachment 02 Lift bench work area ...
Page 39: ...37 10 4 Attachment 04 Electronic data ...
Page 40: ...38 10 5 Attachment 05 Hydraulic system diagram ...
Page 43: ...41 10 8 Attachment 08 Figures ...
Page 46: ...44 ...