 PROCEDURE FOR ELECTROFUSION FITTINGS 

Rev.: 

5

 

 

3.1.5.1

 

Manual data entry: 

 

Is the first choice showed when validated 

1 FUSION

 with 

OK

 key. 

MODE OF USE 

1 MANUAL FUSION 

Validate it by pressing the 

OK

 key. 

 

Electrofusion voltage in a range of 8 and 44 V are only accepted. 

FUSION VOLTAGE: 

U = 40,0 [V] 

U  =  40.0  V  corresponds  to  the  last  entry;  entry  via  the 
keyboard the desired voltage, if different. 

 

Validate with the 

OK

 key to continue or press 

STOP

 to go back to the previous screen. 

FUSION TIME: 

Tf = 400s Ta=ttºC 

tf  =  400s  corresponds  to  the  last  entry;  entry  via  the 
keyboard the desired time, if different. 

 

Ta  =  tt

̊

C  corresponds  to  the  ambient  temperature  (for  information)  for  correcting  the 

electrofusion time based on this merger. 

 

Validate with the 

OK

 key to continue or press 

STOP

 to go back to the previous screen. 

COOLING TIME: 

tc = 11 [min] 

tc  =  11  corresponds  to  the  last  entry;  entry  via  keyboard  the 
desired cooling time, if different

 

Validate with the 

OK

 key to continue or press 

STOP

 to go back to the previous screen. 

 

 

NOTES! 

If  no  fitting  is  connected  to  the  unit’s  electrofusion  cable  terminals, 
the  display  will  show  the  following  message  “NO  FITTING:  CHECK 
WIRES!”. Refer to clause 3.1.6.4 of this 

Manual

 

U=40,0V  tf=400s 
tc =11min   START 

The  display  shows  the  input  parameters  and  the  message 
START making intermittences. 

Press 

START

  to  begin  the  electrofusion  cycle.  Press 

STOP

  to  go  back  to  screen 

1  MANUAL 

FUSION

 

U=40,0V      I=aaA 
tf =400        R=rrΩ 

The  display  shows  the  electrofusion  voltage,  current  and 
time as well as the fitting resistance. 

 

During the electrofusion cycle the 

FUSION

 LED blinks and the buzzer becomes audible. 

Once terminated the fusion cycle, the display shows the cooling time entered: 

 

COOLING: 

tc = 11 [min] 

Where  tc  =  11:00  is  the  entered  time.  Automatically  starts  the 
countdown to the expiration of the time

 

Summary of Contents for LITTLE BEAT

Page 1: ...ELECTROFUSION CONTROL BOX MODEL USER MANUAL ELECTROFUSION CONTROL BOX MODEL LITTLE BEAT Edition October 2019 Revision N 5 Publication MU 78 13EN ELECTROFUSION CONTROL BOX...

Page 2: ...736 61 Napajedla Czech Republic info stp fittings cz 420577913065 STP Acuster Baltics Bullu str 45 Riga LV1067 Latvia riga stpfittings lv 37167815281 STP Acuster South Africa 54 Richard Road Industri...

Page 3: ...S 11 3 1 1 Scraping pipe surfaces 11 3 1 2 Fitting installation 11 3 1 3 Unit connection 12 3 1 4 Fitting connection 13 3 1 5 Entering electrofusion data in the unit 13 3 1 6 Incidents that may occur...

Page 4: ...cifications ISO 12176 2 Equipment for fusion jointing polyethylene systems Part 2 Electrofusion ISO 13950 Plastic pipes and fittings automatic recognition of electrofusion systems It accepts all the i...

Page 5: ...ed could result in minor or moderate injury 1 5 2 Safety measures and dangers Please go by the following safety measures Keep the fusion control box out of the reach of non authorised personnel non qu...

Page 6: ...r applicable personal protective equipment such as hard hat safety glasses etc For indoor fusion jointing work adequate ventilation of the premises must be provided Before using the fusion control box...

Page 7: ...ofusion units LITTLE BEAT to which this declaration relates is in conformity with the following Directives and also the following relating standards Directive Related Specification Model 2014 35 EU An...

Page 8: ...the product proves defective during this period due to the materials or its assembly it will be repaired free of charge including the cost of materials and labour at STPAcuster s Technical Service 3 T...

Page 9: ...ed inside a metal transport box which additionally serves for its protection The front part is formed by a membrane which incorporates tactile push buttons to enter the data a back lit LCD display two...

Page 10: ...s FUSION LED Fusion indicator POWER LED Power indicator START Start push button STOP Stop push button DATA Fusion data push button acc to model OK Validation push button and Arrows to shift menus 0 to...

Page 11: ...will be installed The length of the scraping should be greater than that of the fitting IMPORTANT The scraping of the pipe should generate swarf This ensures the elimination of the pipe s most exteri...

Page 12: ...fitting to be used The switch of the unit will light indicating that there is an electrical power input Now turn on the switch NOTES In case to be activated the user authorization code refer to claus...

Page 13: ...Entering electrofusion data in the unit Validating the previous option appears in the display MODE OF USE 1 MANUAL FUSION Choose this option to carry out a manual electrofusion To view the 3 remaining...

Page 14: ...TOP to go back to the previous screen COOLING TIME tc 11 min tc 11 corresponds to the last entry entry via keyboard the desired cooling time if different Validate with the OK key to continue or press...

Page 15: ...to the previous screen Capture the fitting barcode with the scanner WARNING Make sure you always read the barcode corresponding to the fitting to be electrofused Should you not record the fitting s da...

Page 16: ...e electrofusion cycle the FUSION LED blinks and the buzzer becomes audible Once terminated the fusion cycle the display shows the cooling time entered COOLING tc 11 min Where tc 11 00 is the entered t...

Page 17: ...U 40 0V te 400s tc 11min START The display shows the parameters manually entered and the message START making intermittences NOTES If no fitting is connected to the unit s electrofusion cable terminal...

Page 18: ...ls the display will show the following message NO FITTING CHECK WIRES Refer to clause 3 1 6 4 of this Manual Press START to begin the electrofusion cycle Press STOP to go back to screen 1 MANUAL FUSIO...

Page 19: ...arcode or poorly captured If it is done an incorrectly capture of the barcode through the scanner the display shows the following message READING OF CODE IS IMPOSSIBLE This message appears very briefl...

Page 20: ...C or lower Locate the unit in an area where the ambient temperature is higher than indicated 3 1 6 7 Detection of open circuit or incident If during the electrofusion cycle an incident occurs such as...

Page 21: ...lidating the previous option the display will show SETTINGS 1 DISPLAY Choose this option to set the backlight and contrast To access to the 3 remaining options click on the arrow to move to the next o...

Page 22: ...e PIN number corresponding to the unit s serial number to Acuster Global 3 2 3 Language settings Once validated 2 SETTINGS by pressing OK press two times the arrow to access to this option Press the a...

Page 23: ...n by unqualified personnel beyond these troubleshooting measures in order not to run the risk of seriously damaging the unit 4 1 2 Storage If the unit is not to be used for a long period of time keep...

Page 24: ...terior cleaning of the casing there is no specific maintenance for the electronic control unit Tune ups and adjustments should be performed by qualified personnel or by the STPAcuster s After Sales Se...

Page 25: ...rotection type Double isolation IP55 Duty factor 40 to 90 depending on the fitting size Electronic temperature monitoring of the unit Working temperature 5 to 40 C blocking at 6 C Display LCD 2 lines...

Page 26: ...enerator specifications Frequency 50 Hz Output power 4 kVA minimum Voltage 230 Vac Intensity 12 A min for 230 Vac Voltage control Preferably electronic 5 1 3 Accessories List of accessories included i...

Page 27: ...USER MANUAL MODEL LITTLE BEAT Edition January 2016 NOTES 27 27 Rev 4 RESERVED FOR NOTES...

Reviews: